[media] Fix RC5 decoding with Fintek CIR chipset

Fix RC5 decoding with Fintek CIR chipset

Commit e87b540be2dd02552fb9244d50ae8b4e4619a34b tightened up the RC5
decoding by adding a check for trailing silence to ensure a valid RC5
command had been received. Unfortunately the trailer length checked was
10 units and the Fintek CIR device does not want to provide details of a
space longer than 6350us. This meant that RC5 remotes working on a
Fintek setup on 3.16 failed on 3.17 and later. Fix this by shortening
the trailer check to 6 units (allowing for a previous space in the
received remote command).

Bugzilla: https://bugzilla.kernel.org/show_bug.cgi?id=117221

Signed-off-by: Jonathan McDowell <noodles@earth.li>
Cc: stable@vger.kernel.org
Signed-off-by: David Härdeman <david@hardeman.nu>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
diff --git a/drivers/media/rc/ir-rc5-decoder.c b/drivers/media/rc/ir-rc5-decoder.c
index 6ffe776..a0fd4e6 100644
--- a/drivers/media/rc/ir-rc5-decoder.c
+++ b/drivers/media/rc/ir-rc5-decoder.c
@@ -29,7 +29,7 @@
 #define RC5_BIT_START		(1 * RC5_UNIT)
 #define RC5_BIT_END		(1 * RC5_UNIT)
 #define RC5X_SPACE		(4 * RC5_UNIT)
-#define RC5_TRAILER		(10 * RC5_UNIT) /* In reality, approx 100 */
+#define RC5_TRAILER		(6 * RC5_UNIT) /* In reality, approx 100 */
 
 enum rc5_state {
 	STATE_INACTIVE,