bnx2x: fix non-pmf device load flow
Remove port MAX BW configuration from non-pmf functions,
which caused reconfigure of HW according to 10G (fake) link.
Signed-off-by: Dmitry Kravkov <dmitry@broadcom.com>
Signed-off-by: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/bnx2x/bnx2x_main.c b/drivers/net/bnx2x/bnx2x_main.c
index 032ae18..469ca60 100644
--- a/drivers/net/bnx2x/bnx2x_main.c
+++ b/drivers/net/bnx2x/bnx2x_main.c
@@ -2092,8 +2092,9 @@
bnx2x_calc_vn_weight_sum(bp);
/* calculate and set min-max rate for each vn */
- for (vn = VN_0; vn < E1HVN_MAX; vn++)
- bnx2x_init_vn_minmax(bp, vn);
+ if (bp->port.pmf)
+ for (vn = VN_0; vn < E1HVN_MAX; vn++)
+ bnx2x_init_vn_minmax(bp, vn);
/* always enable rate shaping and fairness */
bp->cmng.flags.cmng_enables |=