bnx2x: fix non-pmf device load flow

Remove port MAX BW configuration from non-pmf functions,
which caused reconfigure of HW according to 10G (fake) link.

Signed-off-by: Dmitry Kravkov <dmitry@broadcom.com>
Signed-off-by: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/bnx2x/bnx2x_main.c b/drivers/net/bnx2x/bnx2x_main.c
index 032ae18..469ca60 100644
--- a/drivers/net/bnx2x/bnx2x_main.c
+++ b/drivers/net/bnx2x/bnx2x_main.c
@@ -2092,8 +2092,9 @@
 		bnx2x_calc_vn_weight_sum(bp);
 
 		/* calculate and set min-max rate for each vn */
-		for (vn = VN_0; vn < E1HVN_MAX; vn++)
-			bnx2x_init_vn_minmax(bp, vn);
+		if (bp->port.pmf)
+			for (vn = VN_0; vn < E1HVN_MAX; vn++)
+				bnx2x_init_vn_minmax(bp, vn);
 
 		/* always enable rate shaping and fairness */
 		bp->cmng.flags.cmng_enables |=