net/rds: use prink_ratelimited() instead of printk_ratelimit()
Since printk_ratelimit() shouldn't be used anymore (see comment in
include/linux/printk.h), replace it with printk_ratelimited()
Signed-off-by: Manuel Zerpies <manuel.f.zerpies@ww.stud.uni-erlangen.de>
Signed-off-by: David S. Miller <davem@conan.davemloft.net>
diff --git a/net/rds/ib_send.c b/net/rds/ib_send.c
index 7c4dce8..e590949 100644
--- a/net/rds/ib_send.c
+++ b/net/rds/ib_send.c
@@ -34,6 +34,7 @@
#include <linux/in.h>
#include <linux/device.h>
#include <linux/dmapool.h>
+#include <linux/ratelimit.h>
#include "rds.h"
#include "ib.h"
@@ -207,8 +208,7 @@
}
break;
default:
- if (printk_ratelimit())
- printk(KERN_NOTICE
+ printk_ratelimited(KERN_NOTICE
"RDS/IB: %s: unexpected opcode 0x%x in WR!\n",
__func__, send->s_wr.opcode);
break;