clocksource: samsung_pwm_timer: Correct definition of AUTORELOAD bit
PWM channel 4 has its autoreload bit located at different position. This
patch fixes the driver to account for that.
This fixes a problem with the clocksource hanging after it overflows because
it is not reloaded any more.
Signed-off-by: Tomasz Figa <tomasz.figa@gmail.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Tested-by: Heiko Stuebner <heiko@sntech.de>
Tested-by: Mark Brown <broonie@linaro.org>
Tested-by: Sylwester Nawrocki <sylvester.nawrocki@gmail.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
1 file changed