x86-64, compat: Retruncate rax after ia32 syscall entry tracing
In commit d4d6715, we reopened an old hole for a 64-bit ptracer touching a
32-bit tracee in system call entry. A %rax value set via ptrace at the
entry tracing stop gets used whole as a 32-bit syscall number, while we
only check the low 32 bits for validity.
Fix it by truncating %rax back to 32 bits after syscall_trace_enter,
in addition to testing the full 64 bits as has already been added.
Reported-by: Ben Hawkes <hawkes@sota.gen.nz>
Signed-off-by: Roland McGrath <roland@redhat.com>
Signed-off-by: H. Peter Anvin <hpa@linux.intel.com>
1 file changed