commit | f1e0001f973cfbec62d702cbd3d56f6b703cc90e | [log] [tgz] |
---|---|---|
author | Tomi Valkeinen <tomi.valkeinen@ti.com> | Tue Mar 05 17:21:35 2013 +0200 |
committer | Tomi Valkeinen <tomi.valkeinen@ti.com> | Wed Apr 03 15:19:18 2013 +0300 |
tree | b78e0b018a32bbd4377e238887ad2eac0b51598a | |
parent | 100c826235793345efe06b3558cc9d36166b1e26 [diff] |
OMAPDSS: DSI: use new clock calculation code Use the new clock calculation code in the DSI driver. The new code does not need DSI video mode parameters from the panel driver, like the old code does. Instead the new code is given the normal video timings, and a few DSI parameters, which are used to create DSI video timings. Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>