serial: max310x: Remove excess port configure at startup

Serial core calls set_termios() after port startup, so there are
no reason to setup port twice.

Signed-off-by: Alexander Shiyan <shc_work@mail.ru>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
diff --git a/drivers/tty/serial/max310x.c b/drivers/tty/serial/max310x.c
index 202c1fb6..1fb3895 100644
--- a/drivers/tty/serial/max310x.c
+++ b/drivers/tty/serial/max310x.c
@@ -896,12 +896,6 @@
 
 	s->devtype->power(port, 1);
 
-	/* Configure baud rate, 9600 as default */
-	max310x_set_baud(port, 9600);
-
-	/* Configure LCR register, 8N1 mode by default */
-	max310x_port_write(port, MAX310X_LCR_REG, MAX310X_LCR_WORD_LEN_8);
-
 	/* Configure MODE1 register */
 	max310x_port_update(port, MAX310X_MODE1_REG,
 			    MAX310X_MODE1_TRNSCVCTRL_BIT,