hwmon: (lm85) Add support for ADT7468 high-frequency PWM mode

The ADT7468 supports a high-frequency PWM output mode where all PWM
outputs are driven by a 22.5 kHz clock. Add support for this mode, and
document it, as it may surprise the user that setting one PWM output
frequency also affects the other PWM outputs.

Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: Darrick J. Wong <djwong@us.ibm.com>
Acked-by: Guenter Roeck <guenter.roeck@ericsson.com>
diff --git a/Documentation/hwmon/lm85 b/Documentation/hwmon/lm85
index 83cd5bb..239258a 100644
--- a/Documentation/hwmon/lm85
+++ b/Documentation/hwmon/lm85
@@ -101,6 +101,13 @@
 described in the documentation. The current lm85 driver does not show the
 offset register.
 
+The ADT7468 has a high-frequency PWM mode, where all PWM outputs are
+driven by a 22.5 kHz clock. This is a global mode, not per-PWM output,
+which means that setting any PWM frequency above 11.3 kHz will switch
+all 3 PWM outputs to a 22.5 kHz frequency. Conversely, setting any PWM
+frequency below 11.3 kHz will switch all 3 PWM outputs to a frequency
+between 10 and 100 Hz, which can then be tuned separately.
+
 See the vendor datasheets for more information. There is application note
 from National (AN-1260) with some additional information about the LM85.
 The Analog Devices datasheet is very detailed and describes a procedure for