| # |
| # PMBus chip drivers configuration |
| # |
| |
| menuconfig PMBUS |
| tristate "PMBus support" |
| depends on I2C |
| default n |
| help |
| Say yes here if you want to enable PMBus support. |
| |
| This driver can also be built as a module. If so, the module will |
| be called pmbus_core. |
| |
| if PMBUS |
| |
| config SENSORS_PMBUS |
| tristate "Generic PMBus devices" |
| default y |
| help |
| If you say yes here you get hardware monitoring support for generic |
| PMBus devices, including but not limited to ADP4000, BMR453, BMR454, |
| MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, UDT020, TPS40400, |
| and TPS40422. |
| |
| This driver can also be built as a module. If so, the module will |
| be called pmbus. |
| |
| config SENSORS_ADM1275 |
| tristate "Analog Devices ADM1275 and compatibles" |
| default n |
| help |
| If you say yes here you get hardware monitoring support for Analog |
| Devices ADM1075, ADM1275, and ADM1276 Hot-Swap Controller and Digital |
| Power Monitors. |
| |
| This driver can also be built as a module. If so, the module will |
| be called adm1275. |
| |
| config SENSORS_LM25066 |
| tristate "National Semiconductor LM25066 and compatibles" |
| default n |
| help |
| If you say yes here you get hardware monitoring support for National |
| Semiconductor LM25066, LM5064, and LM5066. |
| |
| This driver can also be built as a module. If so, the module will |
| be called lm25066. |
| |
| config SENSORS_LTC2978 |
| tristate "Linear Technologies LTC2974, LTC2978, LTC3880, and LTC3883" |
| default n |
| help |
| If you say yes here you get hardware monitoring support for Linear |
| Technology LTC2974, LTC2978, LTC3880, and LTC3883. |
| |
| This driver can also be built as a module. If so, the module will |
| be called ltc2978. |
| |
| config SENSORS_MAX16064 |
| tristate "Maxim MAX16064" |
| default n |
| help |
| If you say yes here you get hardware monitoring support for Maxim |
| MAX16064. |
| |
| This driver can also be built as a module. If so, the module will |
| be called max16064. |
| |
| config SENSORS_MAX34440 |
| tristate "Maxim MAX34440 and compatibles" |
| default n |
| help |
| If you say yes here you get hardware monitoring support for Maxim |
| MAX34440, MAX34441, MAX34446, MAX34460, and MAX34461. |
| |
| This driver can also be built as a module. If so, the module will |
| be called max34440. |
| |
| config SENSORS_MAX8688 |
| tristate "Maxim MAX8688" |
| default n |
| help |
| If you say yes here you get hardware monitoring support for Maxim |
| MAX8688. |
| |
| This driver can also be built as a module. If so, the module will |
| be called max8688. |
| |
| config SENSORS_UCD9000 |
| tristate "TI UCD90120, UCD90124, UCD9090, UCD90910" |
| default n |
| help |
| If you say yes here you get hardware monitoring support for TI |
| UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health |
| Controllers. |
| |
| This driver can also be built as a module. If so, the module will |
| be called ucd9000. |
| |
| config SENSORS_UCD9200 |
| tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248" |
| default n |
| help |
| If you say yes here you get hardware monitoring support for TI |
| UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248 |
| Digital PWM System Controllers. |
| |
| This driver can also be built as a module. If so, the module will |
| be called ucd9200. |
| |
| config SENSORS_ZL6100 |
| tristate "Intersil ZL6100 and compatibles" |
| default n |
| help |
| If you say yes here you get hardware monitoring support for Intersil |
| ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105, |
| ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for |
| Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464. |
| |
| This driver can also be built as a module. If so, the module will |
| be called zl6100. |
| |
| endif # PMBUS |