blob: d949b781f6f8b3df59e3952936e3cec7c5d769da [file] [log] [blame]
Linus Torvalds1da177e2005-04-16 15:20:36 -07001#
2# Block device driver configuration
3#
4
Jan Engelhardtafd44032007-07-17 04:06:11 -07005menuconfig MD
Linus Torvalds1da177e2005-04-16 15:20:36 -07006 bool "Multiple devices driver support (RAID and LVM)"
Jan Engelhardtafd44032007-07-17 04:06:11 -07007 depends on BLOCK
Linus Torvalds1da177e2005-04-16 15:20:36 -07008 help
9 Support multiple physical spindles through a single logical device.
10 Required for RAID and logical volume management.
11
Jan Engelhardtafd44032007-07-17 04:06:11 -070012if MD
13
Linus Torvalds1da177e2005-04-16 15:20:36 -070014config BLK_DEV_MD
15 tristate "RAID support"
Linus Torvalds1da177e2005-04-16 15:20:36 -070016 ---help---
17 This driver lets you combine several hard disk partitions into one
18 logical block device. This can be used to simply append one
19 partition to another one or to combine several redundant hard disks
20 into a RAID1/4/5 device so as to provide protection against hard
21 disk failures. This is called "Software RAID" since the combining of
22 the partitions is done by the kernel. "Hardware RAID" means that the
23 combining is done by a dedicated controller; if you have such a
24 controller, you do not need to say Y here.
25
26 More information about Software RAID on Linux is contained in the
27 Software RAID mini-HOWTO, available from
28 <http://www.tldp.org/docs.html#howto>. There you will also learn
29 where to get the supporting user space utilities raidtools.
30
31 If unsure, say N.
32
Arjan van de Vena3640922008-09-21 15:44:32 -070033config MD_AUTODETECT
34 bool "Autodetect RAID arrays during kernel boot"
Alan Jenkinsce52aeb2008-10-10 16:02:53 +010035 depends on BLK_DEV_MD=y
Arjan van de Vena3640922008-09-21 15:44:32 -070036 default y
37 ---help---
38 If you say Y here, then the kernel will try to autodetect raid
39 arrays as part of its boot process.
40
41 If you don't use raid and say Y, this autodetection can cause
42 a several-second delay in the boot time due to various
43 synchronisation steps that are part of this step.
44
45 If unsure, say Y.
46
Linus Torvalds1da177e2005-04-16 15:20:36 -070047config MD_LINEAR
48 tristate "Linear (append) mode"
49 depends on BLK_DEV_MD
50 ---help---
51 If you say Y here, then your multiple devices driver will be able to
52 use the so-called linear mode, i.e. it will combine the hard disk
53 partitions by simply appending one to the other.
54
55 To compile this as a module, choose M here: the module
56 will be called linear.
57
58 If unsure, say Y.
59
60config MD_RAID0
61 tristate "RAID-0 (striping) mode"
62 depends on BLK_DEV_MD
63 ---help---
64 If you say Y here, then your multiple devices driver will be able to
65 use the so-called raid0 mode, i.e. it will combine the hard disk
66 partitions into one logical device in such a fashion as to fill them
67 up evenly, one chunk here and one chunk there. This will increase
68 the throughput rate if the partitions reside on distinct disks.
69
70 Information about Software RAID on Linux is contained in the
71 Software-RAID mini-HOWTO, available from
72 <http://www.tldp.org/docs.html#howto>. There you will also
73 learn where to get the supporting user space utilities raidtools.
74
75 To compile this as a module, choose M here: the module
76 will be called raid0.
77
78 If unsure, say Y.
79
80config MD_RAID1
81 tristate "RAID-1 (mirroring) mode"
82 depends on BLK_DEV_MD
83 ---help---
84 A RAID-1 set consists of several disk drives which are exact copies
85 of each other. In the event of a mirror failure, the RAID driver
86 will continue to use the operational mirrors in the set, providing
87 an error free MD (multiple device) to the higher levels of the
88 kernel. In a set with N drives, the available space is the capacity
89 of a single drive, and the set protects against a failure of (N - 1)
90 drives.
91
92 Information about Software RAID on Linux is contained in the
93 Software-RAID mini-HOWTO, available from
94 <http://www.tldp.org/docs.html#howto>. There you will also
95 learn where to get the supporting user space utilities raidtools.
96
97 If you want to use such a RAID-1 set, say Y. To compile this code
98 as a module, choose M here: the module will be called raid1.
99
100 If unsure, say Y.
101
102config MD_RAID10
NeilBrown08fb7302010-05-03 13:16:56 +1000103 tristate "RAID-10 (mirrored striping) mode"
104 depends on BLK_DEV_MD
Linus Torvalds1da177e2005-04-16 15:20:36 -0700105 ---help---
106 RAID-10 provides a combination of striping (RAID-0) and
Justin Piszcz4d2554d2006-06-26 00:27:50 -0700107 mirroring (RAID-1) with easier configuration and more flexible
Linus Torvalds1da177e2005-04-16 15:20:36 -0700108 layout.
109 Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110 be the same size (or at least, only as much as the smallest device
111 will be used).
112 RAID-10 provides a variety of layouts that provide different levels
113 of redundancy and performance.
114
115 RAID-10 requires mdadm-1.7.0 or later, available at:
116
117 ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
118
119 If unsure, say Y.
120
NeilBrown16a53ec2006-06-26 00:27:38 -0700121config MD_RAID456
122 tristate "RAID-4/RAID-5/RAID-6 mode"
Linus Torvalds1da177e2005-04-16 15:20:36 -0700123 depends on BLK_DEV_MD
David Woodhousef5e70d02009-07-13 11:35:12 +0100124 select RAID6_PQ
Dan Williams9bc89cd2007-01-02 11:10:44 -0700125 select ASYNC_MEMCPY
126 select ASYNC_XOR
Dan Williamsac6b53b2009-07-14 13:40:19 -0700127 select ASYNC_PQ
128 select ASYNC_RAID6_RECOV
Linus Torvalds1da177e2005-04-16 15:20:36 -0700129 ---help---
130 A RAID-5 set of N drives with a capacity of C MB per drive provides
131 the capacity of C * (N - 1) MB, and protects against a failure
132 of a single drive. For a given sector (row) number, (N - 1) drives
133 contain data sectors, and one drive contains the parity protection.
134 For a RAID-4 set, the parity blocks are present on a single drive,
135 while a RAID-5 set distributes the parity across the drives in one
136 of the available parity distribution methods.
137
NeilBrown16a53ec2006-06-26 00:27:38 -0700138 A RAID-6 set of N drives with a capacity of C MB per drive
139 provides the capacity of C * (N - 2) MB, and protects
140 against a failure of any two drives. For a given sector
141 (row) number, (N - 2) drives contain data sectors, and two
142 drives contains two independent redundancy syndromes. Like
143 RAID-5, RAID-6 distributes the syndromes across the drives
144 in one of the available parity distribution methods.
145
Linus Torvalds1da177e2005-04-16 15:20:36 -0700146 Information about Software RAID on Linux is contained in the
147 Software-RAID mini-HOWTO, available from
148 <http://www.tldp.org/docs.html#howto>. There you will also
149 learn where to get the supporting user space utilities raidtools.
150
NeilBrown16a53ec2006-06-26 00:27:38 -0700151 If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y. To
Linus Torvalds1da177e2005-04-16 15:20:36 -0700152 compile this code as a module, choose M here: the module
NeilBrown16a53ec2006-06-26 00:27:38 -0700153 will be called raid456.
Linus Torvalds1da177e2005-04-16 15:20:36 -0700154
155 If unsure, say Y.
156
Dan Williams07a3b412009-08-29 19:13:13 -0700157config MULTICORE_RAID456
158 bool "RAID-4/RAID-5/RAID-6 Multicore processing (EXPERIMENTAL)"
159 depends on MD_RAID456
160 depends on SMP
161 depends on EXPERIMENTAL
162 ---help---
163 Enable the raid456 module to dispatch per-stripe raid operations to a
164 thread pool.
165
166 If unsure, say N.
167
Linus Torvalds1da177e2005-04-16 15:20:36 -0700168config MD_MULTIPATH
169 tristate "Multipath I/O support"
170 depends on BLK_DEV_MD
171 help
NeilBrown93bd89a2009-12-14 12:49:59 +1100172 MD_MULTIPATH provides a simple multi-path personality for use
173 the MD framework. It is not under active development. New
174 projects should consider using DM_MULTIPATH which has more
175 features and more testing.
Linus Torvalds1da177e2005-04-16 15:20:36 -0700176
177 If unsure, say N.
178
179config MD_FAULTY
180 tristate "Faulty test module for MD"
181 depends on BLK_DEV_MD
182 help
183 The "faulty" module allows for a block device that occasionally returns
184 read or write errors. It is useful for testing.
185
186 In unsure, say N.
187
188config BLK_DEV_DM
189 tristate "Device mapper support"
Linus Torvalds1da177e2005-04-16 15:20:36 -0700190 ---help---
191 Device-mapper is a low level volume manager. It works by allowing
192 people to specify mappings for ranges of logical sectors. Various
193 mapping types are available, in addition people may write their own
194 modules containing custom mappings if they wish.
195
196 Higher level volume managers such as LVM2 use this driver.
197
198 To compile this as a module, choose M here: the module will be
199 called dm-mod.
200
201 If unsure, say N.
202
Bryn Reevescc109202006-10-03 01:15:35 -0700203config DM_DEBUG
204 boolean "Device mapper debugging support"
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000205 depends on BLK_DEV_DM
Bryn Reevescc109202006-10-03 01:15:35 -0700206 ---help---
207 Enable this for messages that may help debug device-mapper problems.
208
209 If unsure, say N.
210
Mikulas Patocka95d402f2011-10-31 20:19:09 +0000211config DM_BUFIO
212 tristate
213 depends on BLK_DEV_DM && EXPERIMENTAL
214 ---help---
215 This interface allows you to do buffered I/O on a device and acts
216 as a cache, holding recently-read blocks in memory and performing
217 delayed writes.
218
Joe Thornber991d9fa2011-10-31 20:21:18 +0000219source "drivers/md/persistent-data/Kconfig"
220
Linus Torvalds1da177e2005-04-16 15:20:36 -0700221config DM_CRYPT
222 tristate "Crypt target support"
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000223 depends on BLK_DEV_DM
Linus Torvalds1da177e2005-04-16 15:20:36 -0700224 select CRYPTO
Herbert Xu32632632006-12-10 09:50:36 +1100225 select CRYPTO_CBC
Linus Torvalds1da177e2005-04-16 15:20:36 -0700226 ---help---
227 This device-mapper target allows you to create a device that
228 transparently encrypts the data on it. You'll need to activate
229 the ciphers you're going to use in the cryptoapi configuration.
230
231 Information on how to use dm-crypt can be found on
232
233 <http://www.saout.de/misc/dm-crypt/>
234
235 To compile this code as a module, choose M here: the module will
236 be called dm-crypt.
237
238 If unsure, say N.
239
240config DM_SNAPSHOT
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000241 tristate "Snapshot target"
242 depends on BLK_DEV_DM
Linus Torvalds1da177e2005-04-16 15:20:36 -0700243 ---help---
Justin Piszcz4d2554d2006-06-26 00:27:50 -0700244 Allow volume managers to take writable snapshots of a device.
Linus Torvalds1da177e2005-04-16 15:20:36 -0700245
Joe Thornber991d9fa2011-10-31 20:21:18 +0000246config DM_THIN_PROVISIONING
247 tristate "Thin provisioning target (EXPERIMENTAL)"
248 depends on BLK_DEV_DM && EXPERIMENTAL
249 select DM_PERSISTENT_DATA
250 ---help---
251 Provides thin provisioning and snapshots that share a data store.
252
253config DM_DEBUG_BLOCK_STACK_TRACING
254 boolean "Keep stack trace of thin provisioning block lock holders"
255 depends on STACKTRACE_SUPPORT && DM_THIN_PROVISIONING
256 select STACKTRACE
257 ---help---
258 Enable this for messages that may help debug problems with the
259 block manager locking used by thin provisioning.
260
261 If unsure, say N.
262
Linus Torvalds1da177e2005-04-16 15:20:36 -0700263config DM_MIRROR
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000264 tristate "Mirror target"
265 depends on BLK_DEV_DM
Linus Torvalds1da177e2005-04-16 15:20:36 -0700266 ---help---
267 Allow volume managers to mirror logical volumes, also
268 needed for live data migration tools such as 'pvmove'.
269
NeilBrown9d09e662011-01-13 20:00:02 +0000270config DM_RAID
NeilBrownd9f691c2012-08-02 08:35:43 +1000271 tristate "RAID 1/4/5/6/10 target"
Alasdair G Kergon035220b2012-03-28 18:41:24 +0100272 depends on BLK_DEV_DM
Jonathan Brassowb12d4372011-08-02 12:32:07 +0100273 select MD_RAID1
NeilBrownd9f691c2012-08-02 08:35:43 +1000274 select MD_RAID10
NeilBrown9d09e662011-01-13 20:00:02 +0000275 select MD_RAID456
276 select BLK_DEV_MD
277 ---help---
NeilBrownd9f691c2012-08-02 08:35:43 +1000278 A dm target that supports RAID1, RAID10, RAID4, RAID5 and RAID6 mappings
NeilBrown9d09e662011-01-13 20:00:02 +0000279
280 A RAID-5 set of N drives with a capacity of C MB per drive provides
281 the capacity of C * (N - 1) MB, and protects against a failure
282 of a single drive. For a given sector (row) number, (N - 1) drives
283 contain data sectors, and one drive contains the parity protection.
284 For a RAID-4 set, the parity blocks are present on a single drive,
285 while a RAID-5 set distributes the parity across the drives in one
286 of the available parity distribution methods.
287
288 A RAID-6 set of N drives with a capacity of C MB per drive
289 provides the capacity of C * (N - 2) MB, and protects
290 against a failure of any two drives. For a given sector
291 (row) number, (N - 2) drives contain data sectors, and two
292 drives contains two independent redundancy syndromes. Like
293 RAID-5, RAID-6 distributes the syndromes across the drives
294 in one of the available parity distribution methods.
295
Jonthan Brassowf5db4af2009-06-22 10:12:35 +0100296config DM_LOG_USERSPACE
297 tristate "Mirror userspace logging (EXPERIMENTAL)"
298 depends on DM_MIRROR && EXPERIMENTAL && NET
299 select CONNECTOR
300 ---help---
301 The userspace logging module provides a mechanism for
302 relaying the dm-dirty-log API to userspace. Log designs
303 which are more suited to userspace implementation (e.g.
304 shared storage logs) or experimental logs can be implemented
305 by leveraging this framework.
306
Linus Torvalds1da177e2005-04-16 15:20:36 -0700307config DM_ZERO
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000308 tristate "Zero target"
309 depends on BLK_DEV_DM
Linus Torvalds1da177e2005-04-16 15:20:36 -0700310 ---help---
311 A target that discards writes, and returns all zeroes for
312 reads. Useful in some recovery situations.
313
314config DM_MULTIPATH
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000315 tristate "Multipath target"
316 depends on BLK_DEV_DM
Chandra Seetharamanfe9233f2008-05-23 18:16:40 -0700317 # nasty syntax but means make DM_MULTIPATH independent
318 # of SCSI_DH if the latter isn't defined but if
319 # it is, DM_MULTIPATH must depend on it. We get a build
320 # error if SCSI_DH=m and DM_MULTIPATH=y
321 depends on SCSI_DH || !SCSI_DH
Linus Torvalds1da177e2005-04-16 15:20:36 -0700322 ---help---
323 Allow volume managers to support multipath hardware.
324
Kiyoshi Uedafd5e0332009-06-22 10:12:27 +0100325config DM_MULTIPATH_QL
326 tristate "I/O Path Selector based on the number of in-flight I/Os"
327 depends on DM_MULTIPATH
328 ---help---
329 This path selector is a dynamic load balancer which selects
330 the path with the least number of in-flight I/Os.
331
332 If unsure, say N.
333
Kiyoshi Uedaf392ba82009-06-22 10:12:28 +0100334config DM_MULTIPATH_ST
335 tristate "I/O Path Selector based on the service time"
336 depends on DM_MULTIPATH
337 ---help---
338 This path selector is a dynamic load balancer which selects
339 the path expected to complete the incoming I/O in the shortest
340 time.
341
342 If unsure, say N.
343
Heinz Mauelshagen26b9f222007-05-09 02:33:06 -0700344config DM_DELAY
345 tristate "I/O delaying target (EXPERIMENTAL)"
346 depends on BLK_DEV_DM && EXPERIMENTAL
347 ---help---
348 A target that delays reads and/or writes and can send
349 them to different devices. Useful for testing.
350
351 If unsure, say N.
352
Mike Anderson51e5b2b2007-10-19 22:48:00 +0100353config DM_UEVENT
Alasdair G Kergone0b215d2012-03-28 18:41:24 +0100354 bool "DM uevents"
355 depends on BLK_DEV_DM
Mike Anderson51e5b2b2007-10-19 22:48:00 +0100356 ---help---
357 Generate udev events for DM events.
358
Josef Bacik3407ef52011-03-24 13:54:24 +0000359config DM_FLAKEY
360 tristate "Flakey target (EXPERIMENTAL)"
361 depends on BLK_DEV_DM && EXPERIMENTAL
362 ---help---
363 A target that intermittently fails I/O for debugging purposes.
364
Mikulas Patockaa4ffc152012-03-28 18:43:38 +0100365config DM_VERITY
366 tristate "Verity target support (EXPERIMENTAL)"
367 depends on BLK_DEV_DM && EXPERIMENTAL
368 select CRYPTO
369 select CRYPTO_HASH
370 select DM_BUFIO
371 ---help---
372 This device-mapper target creates a read-only device that
373 transparently validates the data on one underlying device against
374 a pre-generated tree of cryptographic checksums stored on a second
375 device.
376
377 You'll need to activate the digests you're going to use in the
378 cryptoapi configuration.
379
380 To compile this code as a module, choose M here: the module will
381 be called dm-verity.
382
383 If unsure, say N.
384
Jan Engelhardtafd44032007-07-17 04:06:11 -0700385endif # MD