blob: b3b392fe1f61fbecfe1593ae4e216176505f7407 [file] [log] [blame]
Alexander Popovde03fe22015-10-12 00:08:02 +03001Freescale MPC512x LocalPlus Bus FIFO (called SCLPC in the Reference Manual)
2
3Required properties:
4- compatible: should be "fsl,mpc512x-lpbfifo";
5- reg: should contain the offset and length of SCLPC register set;
6- interrupts: should contain the interrupt specifier for SCLPC; syntax of an
7 interrupt client node is described in interrupt-controller/interrupts.txt;
8- dmas: should contain the DMA specifier for SCLPC as described at
9 dma/dma.txt and dma/mpc512x-dma.txt;
10- dma-names: should be "rx-tx";
11
12Example:
13
14 sclpc@10100 {
15 compatible = "fsl,mpc512x-lpbfifo";
16 reg = <0x10100 0x50>;
17 interrupts = <7 0x8>;
18 dmas = <&dma0 26>;
19 dma-names = "rx-tx";
20 };