Laxman Dewangan | 666a584 | 2013-09-11 14:24:19 -0700 | [diff] [blame^] | 1 | Palmas RTC controller bindings |
| 2 | |
| 3 | Required properties: |
| 4 | - compatible: |
| 5 | - "ti,palmas-rtc" for palma series of the RTC controller |
| 6 | - interrupt-parent: Parent interrupt device, must be handle of palmas node. |
| 7 | - interrupts: Interrupt number of RTC submodule on device. |
| 8 | |
| 9 | Optional properties: |
| 10 | |
| 11 | - ti,backup-battery-chargeable: The Palmas series device like TPS65913 or |
| 12 | TPS80036 supports the backup battery for powering the RTC when main |
| 13 | battery is removed or in very low power state. The backup battery |
| 14 | can be chargeable or non-chargeable. This flag will tells whether |
| 15 | battery is chargeable or not. If charging battery then driver can |
| 16 | enable the charging. |
| 17 | - ti,backup-battery-charge-high-current: Enable high current charging in |
| 18 | backup battery. Device supports the < 100mA and > 100mA charging. |
| 19 | The high current will be > 100mA. Absence of this property will |
| 20 | charge battery to lower current i.e. < 100mA. |
| 21 | |
| 22 | Example: |
| 23 | palmas: tps65913@58 { |
| 24 | ... |
| 25 | palmas_rtc: rtc { |
| 26 | compatible = "ti,palmas-rtc"; |
| 27 | interrupt-parent = <&palmas>; |
| 28 | interrupts = <8 0>; |
| 29 | ti,backup-battery-chargeable; |
| 30 | ti,backup-battery-charge-high-current; |
| 31 | }; |
| 32 | ... |
| 33 | }; |