blob: a94ebb535b6d505d3c68bd1aeea0eeb7f6bbb4f3 [file] [log] [blame]
Zhang Rui203d3d42008-01-17 15:51:08 +08001#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
Zhang Rui63c4ec92008-04-21 16:07:13 +08006 tristate "Generic Thermal sysfs driver"
Zhang Rui203d3d42008-01-17 15:51:08 +08007 help
8 Generic Thermal Sysfs driver offers a generic mechanism for
9 thermal management. Usually it's made up of one or more thermal
10 zone and cooling device.
Len Brown543a9562008-02-07 16:55:08 -050011 Each thermal zone contains its own temperature, trip points,
Zhang Rui203d3d42008-01-17 15:51:08 +080012 cooling devices.
13 All platforms with ACPI thermal support can use this driver.
Zhang Rui63c4ec92008-04-21 16:07:13 +080014 If you want this support, you should say Y or M here.
Rene Herman16d75232008-06-24 19:38:56 +020015
Zhang Rui72e19892012-11-15 09:16:20 +080016if THERMAL
17
Rene Herman16d75232008-06-24 19:38:56 +020018config THERMAL_HWMON
Jean Delvareab924022011-07-28 13:48:40 -070019 bool
Eduardo Valentin0dd88792013-07-03 15:14:28 -040020 prompt "Expose thermal sensors as hwmon device"
Rene Herman16d75232008-06-24 19:38:56 +020021 depends on HWMON=y || HWMON=THERMAL
Jean Delvareab924022011-07-28 13:48:40 -070022 default y
Eduardo Valentin0dd88792013-07-03 15:14:28 -040023 help
24 In case a sensor is registered with the thermal
25 framework, this option will also register it
26 as a hwmon. The sensor will then have the common
27 hwmon sysfs interface.
28
29 Say 'Y' here if you want all thermal sensors to
30 have hwmon sysfs interface too.
Vincenzo Frascino6a92c362012-03-21 12:55:03 -070031
Eduardo Valentin4e5e4702013-07-03 15:35:39 -040032config THERMAL_OF
33 bool
34 prompt "APIs to parse thermal data out of device tree"
35 depends on OF
36 default y
37 help
38 This options provides helpers to add the support to
39 read and parse thermal data definitions out of the
40 device tree blob.
41
42 Say 'Y' here if you need to build thermal infrastructure
43 based on device tree.
44
Punit Agrawal35e94642015-03-03 10:43:03 +000045config THERMAL_WRITABLE_TRIPS
46 bool "Enable writable trip points"
47 help
48 This option allows the system integrator to choose whether
49 trip temperatures can be changed from userspace. The
50 writable trips need to be specified when setting up the
51 thermal zone but the choice here takes precedence.
52
53 Say 'Y' here if you would like to allow userspace tools to
54 change trip temperatures.
55
Durgadoss Ra56757a2012-09-21 14:32:24 +053056choice
57 prompt "Default Thermal governor"
Durgadoss Ra56757a2012-09-21 14:32:24 +053058 default THERMAL_DEFAULT_GOV_STEP_WISE
59 help
60 This option sets which thermal governor shall be loaded at
61 startup. If in doubt, select 'step_wise'.
62
63config THERMAL_DEFAULT_GOV_STEP_WISE
64 bool "step_wise"
Zhang Rui9d185d02013-02-08 20:33:42 +080065 select THERMAL_GOV_STEP_WISE
Durgadoss Ra56757a2012-09-21 14:32:24 +053066 help
67 Use the step_wise governor as default. This throttles the
68 devices one step at a time.
69
70config THERMAL_DEFAULT_GOV_FAIR_SHARE
71 bool "fair_share"
Zhang Rui9d185d02013-02-08 20:33:42 +080072 select THERMAL_GOV_FAIR_SHARE
Durgadoss Ra56757a2012-09-21 14:32:24 +053073 help
74 Use the fair_share governor as default. This throttles the
75 devices based on their 'contribution' to a zone. The
76 contribution should be provided through platform data.
77
78config THERMAL_DEFAULT_GOV_USER_SPACE
79 bool "user_space"
Zhang Rui9d185d02013-02-08 20:33:42 +080080 select THERMAL_GOV_USER_SPACE
Durgadoss Ra56757a2012-09-21 14:32:24 +053081 help
82 Select this if you want to let the user space manage the
Regid Ichiraece238f2013-09-09 00:58:53 +030083 platform thermals.
Zhang Rui72e19892012-11-15 09:16:20 +080084
Javi Merino6b775e82015-03-02 17:17:19 +000085config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
86 bool "power_allocator"
87 select THERMAL_GOV_POWER_ALLOCATOR
88 help
89 Select this if you want to control temperature based on
90 system and device power allocation. This governor can only
91 operate on cooling devices that implement the power API.
92
Durgadoss Ra56757a2012-09-21 14:32:24 +053093endchoice
Zhang Rui72e19892012-11-15 09:16:20 +080094
Zhang Rui9d185d02013-02-08 20:33:42 +080095config THERMAL_GOV_FAIR_SHARE
Zhang Rui72e19892012-11-15 09:16:20 +080096 bool "Fair-share thermal governor"
97 help
98 Enable this to manage platform thermals using fair-share governor.
99
Zhang Rui9d185d02013-02-08 20:33:42 +0800100config THERMAL_GOV_STEP_WISE
Zhang Rui72e19892012-11-15 09:16:20 +0800101 bool "Step_wise thermal governor"
102 help
103 Enable this to manage platform thermals using a simple linear
Luka Perkova8227942013-09-27 20:20:33 +0200104 governor.
Zhang Rui72e19892012-11-15 09:16:20 +0800105
Peter Feuerere4dbf982014-07-22 17:37:13 +0200106config THERMAL_GOV_BANG_BANG
107 bool "Bang Bang thermal governor"
108 default n
109 help
110 Enable this to manage platform thermals using bang bang governor.
111
112 Say 'Y' here if you want to use two point temperature regulation
113 used for fans without throttling. Some fan drivers depend on this
114 governor to be enabled (e.g. acerhdf).
115
Zhang Rui9d185d02013-02-08 20:33:42 +0800116config THERMAL_GOV_USER_SPACE
Zhang Rui72e19892012-11-15 09:16:20 +0800117 bool "User_space thermal governor"
118 help
119 Enable this to let the user space manage the platform thermals.
120
Javi Merino6b775e82015-03-02 17:17:19 +0000121config THERMAL_GOV_POWER_ALLOCATOR
122 bool "Power allocator thermal governor"
Javi Merino6b775e82015-03-02 17:17:19 +0000123 help
124 Enable this to manage platform thermals by dynamically
125 allocating and limiting power to devices.
126
Zhang Rui72e19892012-11-15 09:16:20 +0800127config CPU_THERMAL
Zhang Ruibbf7fc82013-03-26 23:57:01 +0800128 bool "generic cpu cooling support"
Zhang Rui72e19892012-11-15 09:16:20 +0800129 depends on CPU_FREQ
Eduardo Valentin39d99cf2013-09-12 19:26:45 -0400130 depends on THERMAL_OF
Zhang Rui72e19892012-11-15 09:16:20 +0800131 help
132 This implements the generic cpu cooling mechanism through frequency
Eduardo Valentinf7188b32013-04-17 17:12:10 +0000133 reduction. An ACPI version of this already exists
134 (drivers/acpi/processor_thermal.c).
Zhang Rui72e19892012-11-15 09:16:20 +0800135 This will be useful for platforms using the generic thermal interface
136 and not the ACPI interface.
Eduardo Valentinf7188b32013-04-17 17:12:10 +0000137
Zhang Rui72e19892012-11-15 09:16:20 +0800138 If you want this support, you should say Y here.
139
Eduardo Valentinf9df89d2014-01-06 09:04:18 -0400140config CLOCK_THERMAL
141 bool "Generic clock cooling support"
142 depends on COMMON_CLK
143 depends on PM_OPP
144 help
145 This entry implements the generic clock cooling mechanism through
146 frequency clipping. Typically used to cool off co-processors. The
147 device that is configured to use this cooling mechanism will be
148 controlled to reduce clock frequency whenever temperature is high.
149
150 If you want this support, you should say Y here.
151
Amit Daniel Kachhape6e238c2013-02-04 00:30:15 +0000152config THERMAL_EMULATION
153 bool "Thermal emulation mode support"
154 help
155 Enable this option to make a emul_temp sysfs node in thermal zone
156 directory to support temperature emulation. With emulation sysfs node,
157 user can manually input temperature and test the different trip
158 threshold behaviour for simulation purpose.
159
Eduardo Valentin88372952013-03-26 21:38:34 +0000160 WARNING: Be careful while enabling this option on production systems,
161 because userland can easily disable the thermal policy by simply
162 flooding this sysfs node with low temperature values.
163
kongxinwei9a5238a2015-05-20 19:16:37 +0800164config HISI_THERMAL
165 tristate "Hisilicon thermal driver"
Eduardo Valentinf9e2b052015-09-09 20:39:44 -0700166 depends on (ARCH_HISI && CPU_THERMAL && OF) || COMPILE_TEST
kongxinwei9a5238a2015-05-20 19:16:37 +0800167 help
168 Enable this to plug hisilicon's thermal sensor driver into the Linux
169 thermal framework. cpufreq is used as the cooling device to throttle
170 CPUs when the passive trip is crossed.
171
Shawn Guoca3de462013-06-24 14:30:44 +0800172config IMX_THERMAL
173 tristate "Temperature sensor driver for Freescale i.MX SoCs"
174 depends on CPU_THERMAL
175 depends on MFD_SYSCON
176 depends on OF
177 help
178 Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
179 It supports one critical trip point and one passive trip point. The
180 cpufreq is used as the cooling device to throttle CPUs when the
181 passive trip is crossed.
182
Zhang Rui72e19892012-11-15 09:16:20 +0800183config SPEAR_THERMAL
184 bool "SPEAr thermal sensor driver"
Eduardo Valentinaa2937b2015-09-09 20:42:01 -0700185 depends on PLAT_SPEAR || COMPILE_TEST
Zhang Rui72e19892012-11-15 09:16:20 +0800186 depends on OF
187 help
188 Enable this to plug the SPEAr thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200189 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800190
Caesar Wangcbac8f632014-11-24 12:58:59 +0800191config ROCKCHIP_THERMAL
192 tristate "Rockchip thermal driver"
Eduardo Valentin444f9b02015-09-09 20:43:57 -0700193 depends on ARCH_ROCKCHIP || COMPILE_TEST
Caesar Wangcbac8f632014-11-24 12:58:59 +0800194 depends on RESET_CONTROLLER
195 help
196 Rockchip thermal driver provides support for Temperature sensor
197 ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
198 trip point. Cpufreq is used as the cooling device and will throttle
199 CPUs when the Temperature crosses the passive trip point.
200
Zhang Rui72e19892012-11-15 09:16:20 +0800201config RCAR_THERMAL
202 tristate "Renesas R-Car thermal driver"
Laurent Pinchartbeeb5a12013-11-27 02:18:34 +0100203 depends on ARCH_SHMOBILE || COMPILE_TEST
Richard Weinbergerd1c8b042014-01-27 09:40:58 +0100204 depends on HAS_IOMEM
Zhang Rui72e19892012-11-15 09:16:20 +0800205 help
206 Enable this to plug the R-Car thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200207 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800208
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000209config KIRKWOOD_THERMAL
210 tristate "Temperature sensor on Marvell Kirkwood SoCs"
Eduardo Valentin9c8aa952015-09-09 20:44:46 -0700211 depends on MACH_KIRKWOOD || COMPILE_TEST
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000212 depends on OF
213 help
214 Support for the Kirkwood thermal sensor driver into the Linux thermal
215 framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
216
Andrew Lunn74ffa642013-02-06 06:35:26 +0000217config DOVE_THERMAL
218 tristate "Temperature sensor on Marvell Dove SoCs"
Eduardo Valentin07fffd52015-09-09 20:45:25 -0700219 depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
Andrew Lunn74ffa642013-02-06 06:35:26 +0000220 depends on OF
221 help
222 Support for the Dove thermal sensor driver in the Linux thermal
223 framework.
224
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800225config DB8500_THERMAL
226 bool "DB8500 thermal management"
227 depends on ARCH_U8500
228 default y
229 help
230 Adds DB8500 thermal management implementation according to the thermal
231 management framework. A thermal zone with several trip points will be
232 created. Cooling devices can be bound to the trip points to cool this
233 thermal zone if trip points reached.
234
Ezequiel Garciafa0d6542013-04-02 01:37:41 +0000235config ARMADA_THERMAL
236 tristate "Armada 370/XP thermal management"
Eduardo Valentin1b158262015-09-09 20:48:00 -0700237 depends on ARCH_MVEBU || COMPILE_TEST
Ezequiel Garciafa0d6542013-04-02 01:37:41 +0000238 depends on OF
239 help
240 Enable this option if you want to have support for thermal management
241 controller present in Armada 370 and Armada XP SoC.
242
Mikko Perttunen66fb8482014-09-29 17:17:31 +0300243config TEGRA_SOCTHERM
244 tristate "Tegra SOCTHERM thermal management"
245 depends on ARCH_TEGRA
246 help
247 Enable this option for integrated thermal management support on NVIDIA
248 Tegra124 systems-on-chip. The driver supports four thermal zones
249 (CPU, GPU, MEM, PLLX). Cooling devices can be bound to the thermal
250 zones to manage temperatures. This option is also required for the
251 emergency thermal reset (thermtrip) feature to function.
252
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800253config DB8500_CPUFREQ_COOLING
254 tristate "DB8500 cpufreq cooling"
255 depends on ARCH_U8500
256 depends on CPU_THERMAL
257 default y
258 help
259 Adds DB8500 cpufreq cooling devices, and these cooling devices can be
260 bound to thermal zone trip points. When a trip point reached, the
261 bound cpufreq cooling device turns active to set CPU frequency low to
262 cool down the CPU.
Zhang Rui72e19892012-11-15 09:16:20 +0800263
Jacob Pand6d71ee2013-01-21 04:37:57 -0800264config INTEL_POWERCLAMP
265 tristate "Intel PowerClamp idle injection driver"
266 depends on THERMAL
267 depends on X86
268 depends on CPU_SUP_INTEL
269 help
270 Enable this to enable Intel PowerClamp idle injection driver. This
271 enforce idle time which results in more package C-state residency. The
272 user interface is exposed via generic thermal framework.
273
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000274config X86_PKG_TEMP_THERMAL
275 tristate "X86 package temperature thermal driver"
Randy Dunlapb3ba0202013-06-17 12:27:17 -0700276 depends on X86_THERMAL_VECTOR
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000277 select THERMAL_GOV_USER_SPACE
Srinivas Pandruvada98cadf22015-08-03 04:13:16 -0700278 select THERMAL_WRITABLE_TRIPS
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000279 default m
280 help
281 Enable this to register CPU digital sensor for package temperature as
282 thermal zone. Each package will have its own thermal zone. There are
283 two trip points which can be set by user to get notifications via thermal
284 notification methods.
285
Srinivas Pandruvadaee073602015-03-02 13:12:58 -0800286config INTEL_SOC_DTS_IOSF_CORE
287 tristate
288 depends on X86
289 select IOSF_MBI
290 help
291 This is becoming a common feature for Intel SoCs to expose the additional
292 digital temperature sensors (DTSs) using side band interface (IOSF). This
293 implements the common set of helper functions to register, get temperature
294 and get/set thresholds on DTSs.
295
Srinivas Pandruvadabc40b5e2014-04-07 13:57:15 -0700296config INTEL_SOC_DTS_THERMAL
297 tristate "Intel SoCs DTS thermal driver"
Srinivas Pandruvada3a2419f2015-03-02 13:12:59 -0800298 depends on X86
299 select INTEL_SOC_DTS_IOSF_CORE
Srinivas Pandruvada98cadf22015-08-03 04:13:16 -0700300 select THERMAL_WRITABLE_TRIPS
Srinivas Pandruvadabc40b5e2014-04-07 13:57:15 -0700301 help
302 Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
303 temperature sensor (DTS). These SoCs have two additional DTSs in
304 addition to DTSs on CPU cores. Each DTS will be registered as a
305 thermal zone. There are two trip points. One of the trip point can
306 be set by user mode programs to get notifications via Linux thermal
307 notification methods.The other trip is a critical trip point, which
308 was set by the driver based on the TJ MAX temperature.
309
Ong, Boon Leong8c187692015-04-15 10:08:15 +0800310config INTEL_QUARK_DTS_THERMAL
311 tristate "Intel Quark DTS thermal driver"
312 depends on X86_INTEL_QUARK
313 help
314 Enable this to register Intel Quark SoC (e.g. X1000) platform digital
315 temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
316 The DTS will be registered as a thermal zone. There are two trip points:
317 hot & critical. The critical trip point default value is set by
318 underlying BIOS/Firmware.
319
Zhang Rui3230bbf2014-03-14 00:34:05 +0800320config INT340X_THERMAL
Zhang Rui816cab92014-03-14 12:45:05 +0800321 tristate "ACPI INT340X thermal drivers"
Zhang Rui3230bbf2014-03-14 00:34:05 +0800322 depends on X86 && ACPI
Zhang Rui0ab15362014-03-23 23:37:32 +0800323 select THERMAL_GOV_USER_SPACE
Jacob Pan52b1c692014-09-03 15:14:23 +0800324 select ACPI_THERMAL_REL
Zhang Ruid8054742014-06-19 15:43:29 +0800325 select ACPI_FAN
Srinivas Pandruvada4d0dd6c2015-03-02 13:13:00 -0800326 select INTEL_SOC_DTS_IOSF_CORE
Srinivas Pandruvada98cadf22015-08-03 04:13:16 -0700327 select THERMAL_WRITABLE_TRIPS
Zhang Rui3230bbf2014-03-14 00:34:05 +0800328 help
329 Newer laptops and tablets that use ACPI may have thermal sensors and
330 other devices with thermal control capabilities outside the core
331 CPU/SOC, for thermal safety reasons.
332 They are exposed for the OS to use via the INT3400 ACPI device object
333 as the master, and INT3401~INT340B ACPI device objects as the slaves.
334 Enable this to expose the temperature information and cooling ability
335 from these objects to userspace via the normal thermal framework.
336 This means that a wide range of applications and GUI widgets can show
337 the information to the user or use this information for making
338 decisions. For example, the Intel Thermal Daemon can use this
339 information to allow the user to select his laptop to run without
340 turning on the fans.
341
Jacob Pan52b1c692014-09-03 15:14:23 +0800342config ACPI_THERMAL_REL
343 tristate
344 depends on ACPI
345
Tushar Daved0a12622015-06-10 13:34:24 -0700346config INTEL_PCH_THERMAL
347 tristate "Intel PCH Thermal Reporting Driver"
348 depends on X86 && PCI
349 help
350 Enable this to support thermal reporting on certain intel PCHs.
351 Thermal reporting device will provide temperature reading,
352 programmable trip points and other information.
353
Eduardo Valentineb982002013-05-15 15:46:00 +0000354menu "Texas Instruments thermal drivers"
Eduardo Valentinec2feb42015-09-09 21:13:41 -0700355depends on ARCH_HAS_BANDGAP || COMPILE_TEST
Eduardo Valentineb982002013-05-15 15:46:00 +0000356source "drivers/thermal/ti-soc-thermal/Kconfig"
357endmenu
Zhang Ruif157f592013-06-18 06:31:26 +0800358
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530359menu "Samsung thermal drivers"
Eduardo Valentin2bf42732015-09-09 20:53:35 -0700360depends on ARCH_EXYNOS || COMPILE_TEST
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530361source "drivers/thermal/samsung/Kconfig"
362endmenu
363
Lee Jones60aef7c2014-06-05 16:06:55 +0100364menu "STMicroelectronics thermal drivers"
365depends on ARCH_STI && OF
366source "drivers/thermal/st/Kconfig"
367endmenu
368
Ivan T. Ivanovc610afa2015-02-05 19:12:56 +0200369config QCOM_SPMI_TEMP_ALARM
370 tristate "Qualcomm SPMI PMIC Temperature Alarm"
Eduardo Valentincb7fb4d2015-09-09 20:56:26 -0700371 depends on OF && (SPMI || COMPILE_TEST) && IIO
Ivan T. Ivanovc610afa2015-02-05 19:12:56 +0200372 select REGMAP_SPMI
373 help
374 This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
375 PMIC devices. It shows up in sysfs as a thermal sensor with multiple
376 trip points. The temperature reported by the thermal sensor reflects the
377 real time die temperature if an ADC is present or an estimate of the
378 temperature based upon the over temperature stage value.
379