blob: bdcba154b83e1ec72ee7692131abfdcf320b268a [file] [log] [blame]
Henrik Rydbergeacaad02009-04-28 07:49:21 -07001Multi-touch (MT) Protocol
2-------------------------
3 Copyright (C) 2009 Henrik Rydberg <rydberg@euromail.se>
4
5
6Introduction
7------------
8
Henrik Rydberg72c8a942010-07-15 23:22:07 -07009In order to utilize the full power of the new multi-touch and multi-user
10devices, a way to report detailed data from multiple contacts, i.e.,
11objects in direct contact with the device surface, is needed. This
12document describes the multi-touch (MT) protocol which allows kernel
13drivers to report details for an arbitrary number of contacts.
14
15The protocol is divided into two types, depending on the capabilities of the
16hardware. For devices handling anonymous contacts (type A), the protocol
17describes how to send the raw data for all contacts to the receiver. For
18devices capable of tracking identifiable contacts (type B), the protocol
19describes how to send updates for individual contacts via event slots.
Henrik Rydbergeacaad02009-04-28 07:49:21 -070020
21
Henrik Rydberg72c8a942010-07-15 23:22:07 -070022Protocol Usage
23--------------
Henrik Rydbergeacaad02009-04-28 07:49:21 -070024
Henrik Rydberg72c8a942010-07-15 23:22:07 -070025Contact details are sent sequentially as separate packets of ABS_MT
26events. Only the ABS_MT events are recognized as part of a contact
27packet. Since these events are ignored by current single-touch (ST)
28applications, the MT protocol can be implemented on top of the ST protocol
29in an existing driver.
30
31Drivers for type A devices separate contact packets by calling
32input_mt_sync() at the end of each packet. This generates a SYN_MT_REPORT
33event, which instructs the receiver to accept the data for the current
34contact and prepare to receive another.
35
36Drivers for type B devices separate contact packets by calling
37input_mt_slot(), with a slot as argument, at the beginning of each packet.
38This generates an ABS_MT_SLOT event, which instructs the receiver to
39prepare for updates of the given slot.
40
41All drivers mark the end of a multi-touch transfer by calling the usual
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -070042input_sync() function. This instructs the receiver to act upon events
Henrik Rydberg72c8a942010-07-15 23:22:07 -070043accumulated since last EV_SYN/SYN_REPORT and prepare to receive a new set
44of events/packets.
45
46The main difference between the stateless type A protocol and the stateful
47type B slot protocol lies in the usage of identifiable contacts to reduce
48the amount of data sent to userspace. The slot protocol requires the use of
49the ABS_MT_TRACKING_ID, either provided by the hardware or computed from
50the raw data [5].
51
52For type A devices, the kernel driver should generate an arbitrary
53enumeration of the full set of anonymous contacts currently on the
54surface. The order in which the packets appear in the event stream is not
55important. Event filtering and finger tracking is left to user space [3].
56
57For type B devices, the kernel driver should associate a slot with each
58identified contact, and use that slot to propagate changes for the contact.
59Creation, replacement and destruction of contacts is achieved by modifying
60the ABS_MT_TRACKING_ID of the associated slot. A non-negative tracking id
61is interpreted as a contact, and the value -1 denotes an unused slot. A
62tracking id not previously present is considered new, and a tracking id no
63longer present is considered removed. Since only changes are propagated,
64the full state of each initiated contact has to reside in the receiving
65end. Upon receiving an MT event, one simply updates the appropriate
66attribute of the current slot.
67
68
69Protocol Example A
70------------------
71
72Here is what a minimal event sequence for a two-contact touch would look
73like for a type A device:
74
75 ABS_MT_POSITION_X x[0]
76 ABS_MT_POSITION_Y y[0]
77 SYN_MT_REPORT
78 ABS_MT_POSITION_X x[1]
79 ABS_MT_POSITION_Y y[1]
80 SYN_MT_REPORT
81 SYN_REPORT
82
83The sequence after moving one of the contacts looks exactly the same; the
84raw data for all present contacts are sent between every synchronization
85with SYN_REPORT.
86
87Here is the sequence after lifting the first contact:
88
89 ABS_MT_POSITION_X x[1]
90 ABS_MT_POSITION_Y y[1]
91 SYN_MT_REPORT
92 SYN_REPORT
93
94And here is the sequence after lifting the second contact:
95
96 SYN_MT_REPORT
97 SYN_REPORT
98
99If the driver reports one of BTN_TOUCH or ABS_PRESSURE in addition to the
100ABS_MT events, the last SYN_MT_REPORT event may be omitted. Otherwise, the
101last SYN_REPORT will be dropped by the input core, resulting in no
102zero-contact event reaching userland.
103
104
105Protocol Example B
106------------------
107
108Here is what a minimal event sequence for a two-contact touch would look
109like for a type B device:
110
111 ABS_MT_SLOT 0
112 ABS_MT_TRACKING_ID 45
113 ABS_MT_POSITION_X x[0]
114 ABS_MT_POSITION_Y y[0]
115 ABS_MT_SLOT 1
116 ABS_MT_TRACKING_ID 46
117 ABS_MT_POSITION_X x[1]
118 ABS_MT_POSITION_Y y[1]
119 SYN_REPORT
120
121Here is the sequence after moving contact 45 in the x direction:
122
123 ABS_MT_SLOT 0
124 ABS_MT_POSITION_X x[0]
125 SYN_REPORT
126
127Here is the sequence after lifting the contact in slot 0:
128
129 ABS_MT_TRACKING_ID -1
130 SYN_REPORT
131
132The slot being modified is already 0, so the ABS_MT_SLOT is omitted. The
133message removes the association of slot 0 with contact 45, thereby
134destroying contact 45 and freeing slot 0 to be reused for another contact.
135
136Finally, here is the sequence after lifting the second contact:
137
138 ABS_MT_SLOT 1
139 ABS_MT_TRACKING_ID -1
140 SYN_REPORT
141
142
143Event Usage
144-----------
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700145
146A set of ABS_MT events with the desired properties is defined. The events
147are divided into categories, to allow for partial implementation. The
Henrik Rydbergf6bdc232010-01-28 22:28:28 -0800148minimum set consists of ABS_MT_POSITION_X and ABS_MT_POSITION_Y, which
Henrik Rydberg72c8a942010-07-15 23:22:07 -0700149allows for multiple contacts to be tracked. If the device supports it, the
Henrik Rydbergf6bdc232010-01-28 22:28:28 -0800150ABS_MT_TOUCH_MAJOR and ABS_MT_WIDTH_MAJOR may be used to provide the size
Henrik Rydberg72c8a942010-07-15 23:22:07 -0700151of the contact area and approaching contact, respectively.
Henrik Rydbergf6bdc232010-01-28 22:28:28 -0800152
153The TOUCH and WIDTH parameters have a geometrical interpretation; imagine
154looking through a window at someone gently holding a finger against the
155glass. You will see two regions, one inner region consisting of the part
156of the finger actually touching the glass, and one outer region formed by
157the perimeter of the finger. The diameter of the inner region is the
158ABS_MT_TOUCH_MAJOR, the diameter of the outer region is
159ABS_MT_WIDTH_MAJOR. Now imagine the person pressing the finger harder
160against the glass. The inner region will increase, and in general, the
161ratio ABS_MT_TOUCH_MAJOR / ABS_MT_WIDTH_MAJOR, which is always smaller than
Henrik Rydberg72c8a942010-07-15 23:22:07 -0700162unity, is related to the contact pressure. For pressure-based devices,
Henrik Rydbergf6bdc232010-01-28 22:28:28 -0800163ABS_MT_PRESSURE may be used to provide the pressure on the contact area
164instead.
165
Henrik Rydberg72c8a942010-07-15 23:22:07 -0700166In addition to the MAJOR parameters, the oval shape of the contact can be
Henrik Rydbergf6bdc232010-01-28 22:28:28 -0800167described by adding the MINOR parameters, such that MAJOR and MINOR are the
168major and minor axis of an ellipse. Finally, the orientation of the oval
169shape can be describe with the ORIENTATION parameter.
170
171The ABS_MT_TOOL_TYPE may be used to specify whether the touching tool is a
Henrik Rydberg72c8a942010-07-15 23:22:07 -0700172contact or a pen or something else. Devices with more granular information
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700173may specify general shapes as blobs, i.e., as a sequence of rectangular
174shapes grouped together by an ABS_MT_BLOB_ID. Finally, for the few devices
175that currently support it, the ABS_MT_TRACKING_ID event may be used to
Henrik Rydberg72c8a942010-07-15 23:22:07 -0700176report contact tracking from hardware [5].
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700177
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700178
179Event Semantics
180---------------
181
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700182ABS_MT_TOUCH_MAJOR
183
184The length of the major axis of the contact. The length should be given in
185surface units. If the surface has an X times Y resolution, the largest
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700186possible value of ABS_MT_TOUCH_MAJOR is sqrt(X^2 + Y^2), the diagonal [4].
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700187
188ABS_MT_TOUCH_MINOR
189
190The length, in surface units, of the minor axis of the contact. If the
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700191contact is circular, this event can be omitted [4].
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700192
193ABS_MT_WIDTH_MAJOR
194
195The length, in surface units, of the major axis of the approaching
196tool. This should be understood as the size of the tool itself. The
197orientation of the contact and the approaching tool are assumed to be the
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700198same [4].
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700199
200ABS_MT_WIDTH_MINOR
201
202The length, in surface units, of the minor axis of the approaching
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700203tool. Omit if circular [4].
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700204
205The above four values can be used to derive additional information about
206the contact. The ratio ABS_MT_TOUCH_MAJOR / ABS_MT_WIDTH_MAJOR approximates
207the notion of pressure. The fingers of the hand and the palm all have
208different characteristic widths [1].
209
Henrik Rydbergf6bdc232010-01-28 22:28:28 -0800210ABS_MT_PRESSURE
211
212The pressure, in arbitrary units, on the contact area. May be used instead
213of TOUCH and WIDTH for pressure-based devices or any device with a spatial
214signal intensity distribution.
215
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700216ABS_MT_ORIENTATION
217
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700218The orientation of the ellipse. The value should describe a signed quarter
219of a revolution clockwise around the touch center. The signed value range
220is arbitrary, but zero should be returned for a finger aligned along the Y
221axis of the surface, a negative value when finger is turned to the left, and
222a positive value when finger turned to the right. When completely aligned with
223the X axis, the range max should be returned. Orientation can be omitted
224if the touching object is circular, or if the information is not available
225in the kernel driver. Partial orientation support is possible if the device
226can distinguish between the two axis, but not (uniquely) any values in
227between. In such cases, the range of ABS_MT_ORIENTATION should be [0, 1]
228[4].
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700229
230ABS_MT_POSITION_X
231
232The surface X coordinate of the center of the touching ellipse.
233
234ABS_MT_POSITION_Y
235
236The surface Y coordinate of the center of the touching ellipse.
237
238ABS_MT_TOOL_TYPE
239
240The type of approaching tool. A lot of kernel drivers cannot distinguish
241between different tool types, such as a finger or a pen. In such cases, the
242event should be omitted. The protocol currently supports MT_TOOL_FINGER and
243MT_TOOL_PEN [2].
244
245ABS_MT_BLOB_ID
246
247The BLOB_ID groups several packets together into one arbitrarily shaped
Henrik Rydberg72c8a942010-07-15 23:22:07 -0700248contact. This is a low-level anonymous grouping for type A devices, and
249should not be confused with the high-level trackingID [5]. Most type A
250devices do not have blob capability, so drivers can safely omit this event.
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700251
252ABS_MT_TRACKING_ID
253
254The TRACKING_ID identifies an initiated contact throughout its life cycle
Henrik Rydberg72c8a942010-07-15 23:22:07 -0700255[5]. This event is mandatory for type B devices. The value range of the
256TRACKING_ID should be large enough to ensure unique identification of a
257contact maintained over an extended period of time.
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700258
259
260Event Computation
261-----------------
262
263The flora of different hardware unavoidably leads to some devices fitting
264better to the MT protocol than others. To simplify and unify the mapping,
265this section gives recipes for how to compute certain events.
266
267For devices reporting contacts as rectangular shapes, signed orientation
268cannot be obtained. Assuming X and Y are the lengths of the sides of the
269touching rectangle, here is a simple formula that retains the most
270information possible:
271
272 ABS_MT_TOUCH_MAJOR := max(X, Y)
273 ABS_MT_TOUCH_MINOR := min(X, Y)
274 ABS_MT_ORIENTATION := bool(X > Y)
275
276The range of ABS_MT_ORIENTATION should be set to [0, 1], to indicate that
277the device can distinguish between a finger along the Y axis (0) and a
278finger along the X axis (1).
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700279
280
281Finger Tracking
282---------------
283
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700284The process of finger tracking, i.e., to assign a unique trackingID to each
Henrik Rydberg72c8a942010-07-15 23:22:07 -0700285initiated contact on the surface, is a Euclidian Bipartite Matching
286problem. At each event synchronization, the set of actual contacts is
287matched to the set of contacts from the previous synchronization. A full
288implementation can be found in [3].
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700289
290
Henrik Rydbergf6bdc232010-01-28 22:28:28 -0800291Gestures
292--------
293
294In the specific application of creating gesture events, the TOUCH and WIDTH
295parameters can be used to, e.g., approximate finger pressure or distinguish
296between index finger and thumb. With the addition of the MINOR parameters,
297one can also distinguish between a sweeping finger and a pointing finger,
298and with ORIENTATION, one can detect twisting of fingers.
299
300
Henrik Rydbergeacaad02009-04-28 07:49:21 -0700301Notes
302-----
303
304In order to stay compatible with existing applications, the data
305reported in a finger packet must not be recognized as single-touch
306events. In addition, all finger data must bypass input filtering,
307since subsequent events of the same type refer to different fingers.
308
309The first kernel driver to utilize the MT protocol is the bcm5974 driver,
310where examples can be found.
311
312[1] With the extension ABS_MT_APPROACH_X and ABS_MT_APPROACH_Y, the
313difference between the contact position and the approaching tool position
314could be used to derive tilt.
315[2] The list can of course be extended.
Henrik Rydberg13bad372010-03-21 22:31:26 -0700316[3] Multitouch X driver project: http://bitmath.org/code/multitouch/.
Henrik Rydbergf9fcfc32009-05-23 09:51:21 -0700317[4] See the section on event computation.
318[5] See the section on finger tracking.