blob: 30b426ed744bd20de9766b969c9837a292622b85 [file] [log] [blame]
Linus Torvalds1da177e2005-04-16 15:20:36 -07001#
2# Block device driver configuration
3#
4
Jan Engelhardtafd44032007-07-17 04:06:11 -07005menuconfig MD
Linus Torvalds1da177e2005-04-16 15:20:36 -07006 bool "Multiple devices driver support (RAID and LVM)"
Jan Engelhardtafd44032007-07-17 04:06:11 -07007 depends on BLOCK
Linus Torvalds1da177e2005-04-16 15:20:36 -07008 help
9 Support multiple physical spindles through a single logical device.
10 Required for RAID and logical volume management.
11
Jan Engelhardtafd44032007-07-17 04:06:11 -070012if MD
13
Linus Torvalds1da177e2005-04-16 15:20:36 -070014config BLK_DEV_MD
15 tristate "RAID support"
Linus Torvalds1da177e2005-04-16 15:20:36 -070016 ---help---
17 This driver lets you combine several hard disk partitions into one
18 logical block device. This can be used to simply append one
19 partition to another one or to combine several redundant hard disks
20 into a RAID1/4/5 device so as to provide protection against hard
21 disk failures. This is called "Software RAID" since the combining of
22 the partitions is done by the kernel. "Hardware RAID" means that the
23 combining is done by a dedicated controller; if you have such a
24 controller, you do not need to say Y here.
25
26 More information about Software RAID on Linux is contained in the
27 Software RAID mini-HOWTO, available from
28 <http://www.tldp.org/docs.html#howto>. There you will also learn
29 where to get the supporting user space utilities raidtools.
30
31 If unsure, say N.
32
Arjan van de Vena3640922008-09-21 15:44:32 -070033config MD_AUTODETECT
34 bool "Autodetect RAID arrays during kernel boot"
Alan Jenkinsce52aeb2008-10-10 16:02:53 +010035 depends on BLK_DEV_MD=y
Arjan van de Vena3640922008-09-21 15:44:32 -070036 default y
37 ---help---
38 If you say Y here, then the kernel will try to autodetect raid
39 arrays as part of its boot process.
40
41 If you don't use raid and say Y, this autodetection can cause
42 a several-second delay in the boot time due to various
43 synchronisation steps that are part of this step.
44
45 If unsure, say Y.
46
Linus Torvalds1da177e2005-04-16 15:20:36 -070047config MD_LINEAR
48 tristate "Linear (append) mode"
49 depends on BLK_DEV_MD
50 ---help---
51 If you say Y here, then your multiple devices driver will be able to
52 use the so-called linear mode, i.e. it will combine the hard disk
53 partitions by simply appending one to the other.
54
55 To compile this as a module, choose M here: the module
56 will be called linear.
57
58 If unsure, say Y.
59
60config MD_RAID0
61 tristate "RAID-0 (striping) mode"
62 depends on BLK_DEV_MD
63 ---help---
64 If you say Y here, then your multiple devices driver will be able to
65 use the so-called raid0 mode, i.e. it will combine the hard disk
66 partitions into one logical device in such a fashion as to fill them
67 up evenly, one chunk here and one chunk there. This will increase
68 the throughput rate if the partitions reside on distinct disks.
69
70 Information about Software RAID on Linux is contained in the
71 Software-RAID mini-HOWTO, available from
72 <http://www.tldp.org/docs.html#howto>. There you will also
73 learn where to get the supporting user space utilities raidtools.
74
75 To compile this as a module, choose M here: the module
76 will be called raid0.
77
78 If unsure, say Y.
79
80config MD_RAID1
81 tristate "RAID-1 (mirroring) mode"
82 depends on BLK_DEV_MD
83 ---help---
84 A RAID-1 set consists of several disk drives which are exact copies
85 of each other. In the event of a mirror failure, the RAID driver
86 will continue to use the operational mirrors in the set, providing
87 an error free MD (multiple device) to the higher levels of the
88 kernel. In a set with N drives, the available space is the capacity
89 of a single drive, and the set protects against a failure of (N - 1)
90 drives.
91
92 Information about Software RAID on Linux is contained in the
93 Software-RAID mini-HOWTO, available from
94 <http://www.tldp.org/docs.html#howto>. There you will also
95 learn where to get the supporting user space utilities raidtools.
96
97 If you want to use such a RAID-1 set, say Y. To compile this code
98 as a module, choose M here: the module will be called raid1.
99
100 If unsure, say Y.
101
102config MD_RAID10
NeilBrown08fb7302010-05-03 13:16:56 +1000103 tristate "RAID-10 (mirrored striping) mode"
104 depends on BLK_DEV_MD
Linus Torvalds1da177e2005-04-16 15:20:36 -0700105 ---help---
106 RAID-10 provides a combination of striping (RAID-0) and
Justin Piszcz4d2554d2006-06-26 00:27:50 -0700107 mirroring (RAID-1) with easier configuration and more flexible
Linus Torvalds1da177e2005-04-16 15:20:36 -0700108 layout.
109 Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110 be the same size (or at least, only as much as the smallest device
111 will be used).
112 RAID-10 provides a variety of layouts that provide different levels
113 of redundancy and performance.
114
115 RAID-10 requires mdadm-1.7.0 or later, available at:
116
117 ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
118
119 If unsure, say Y.
120
NeilBrown16a53ec2006-06-26 00:27:38 -0700121config MD_RAID456
122 tristate "RAID-4/RAID-5/RAID-6 mode"
Linus Torvalds1da177e2005-04-16 15:20:36 -0700123 depends on BLK_DEV_MD
David Woodhousef5e70d02009-07-13 11:35:12 +0100124 select RAID6_PQ
Dan Williams9bc89cd2007-01-02 11:10:44 -0700125 select ASYNC_MEMCPY
126 select ASYNC_XOR
Dan Williamsac6b53b2009-07-14 13:40:19 -0700127 select ASYNC_PQ
128 select ASYNC_RAID6_RECOV
Linus Torvalds1da177e2005-04-16 15:20:36 -0700129 ---help---
130 A RAID-5 set of N drives with a capacity of C MB per drive provides
131 the capacity of C * (N - 1) MB, and protects against a failure
132 of a single drive. For a given sector (row) number, (N - 1) drives
133 contain data sectors, and one drive contains the parity protection.
134 For a RAID-4 set, the parity blocks are present on a single drive,
135 while a RAID-5 set distributes the parity across the drives in one
136 of the available parity distribution methods.
137
NeilBrown16a53ec2006-06-26 00:27:38 -0700138 A RAID-6 set of N drives with a capacity of C MB per drive
139 provides the capacity of C * (N - 2) MB, and protects
140 against a failure of any two drives. For a given sector
141 (row) number, (N - 2) drives contain data sectors, and two
142 drives contains two independent redundancy syndromes. Like
143 RAID-5, RAID-6 distributes the syndromes across the drives
144 in one of the available parity distribution methods.
145
Linus Torvalds1da177e2005-04-16 15:20:36 -0700146 Information about Software RAID on Linux is contained in the
147 Software-RAID mini-HOWTO, available from
148 <http://www.tldp.org/docs.html#howto>. There you will also
149 learn where to get the supporting user space utilities raidtools.
150
NeilBrown16a53ec2006-06-26 00:27:38 -0700151 If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y. To
Linus Torvalds1da177e2005-04-16 15:20:36 -0700152 compile this code as a module, choose M here: the module
NeilBrown16a53ec2006-06-26 00:27:38 -0700153 will be called raid456.
Linus Torvalds1da177e2005-04-16 15:20:36 -0700154
155 If unsure, say Y.
156
Linus Torvalds1da177e2005-04-16 15:20:36 -0700157config MD_MULTIPATH
158 tristate "Multipath I/O support"
159 depends on BLK_DEV_MD
160 help
NeilBrown93bd89a2009-12-14 12:49:59 +1100161 MD_MULTIPATH provides a simple multi-path personality for use
162 the MD framework. It is not under active development. New
163 projects should consider using DM_MULTIPATH which has more
164 features and more testing.
Linus Torvalds1da177e2005-04-16 15:20:36 -0700165
166 If unsure, say N.
167
168config MD_FAULTY
169 tristate "Faulty test module for MD"
170 depends on BLK_DEV_MD
171 help
172 The "faulty" module allows for a block device that occasionally returns
173 read or write errors. It is useful for testing.
174
175 In unsure, say N.
176
Kent Overstreetcafe5632013-03-23 16:11:31 -0700177source "drivers/md/bcache/Kconfig"
178
Linus Torvalds1da177e2005-04-16 15:20:36 -0700179config BLK_DEV_DM
180 tristate "Device mapper support"
Linus Torvalds1da177e2005-04-16 15:20:36 -0700181 ---help---
182 Device-mapper is a low level volume manager. It works by allowing
183 people to specify mappings for ranges of logical sectors. Various
184 mapping types are available, in addition people may write their own
185 modules containing custom mappings if they wish.
186
187 Higher level volume managers such as LVM2 use this driver.
188
189 To compile this as a module, choose M here: the module will be
190 called dm-mod.
191
192 If unsure, say N.
193
Bryn Reevescc109202006-10-03 01:15:35 -0700194config DM_DEBUG
195 boolean "Device mapper debugging support"
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000196 depends on BLK_DEV_DM
Bryn Reevescc109202006-10-03 01:15:35 -0700197 ---help---
198 Enable this for messages that may help debug device-mapper problems.
199
200 If unsure, say N.
201
Mikulas Patocka95d402f2011-10-31 20:19:09 +0000202config DM_BUFIO
203 tristate
Alasdair G Kergond57916a2013-03-01 22:45:46 +0000204 depends on BLK_DEV_DM
Mikulas Patocka95d402f2011-10-31 20:19:09 +0000205 ---help---
206 This interface allows you to do buffered I/O on a device and acts
207 as a cache, holding recently-read blocks in memory and performing
208 delayed writes.
209
Mike Snitzer4f81a412012-10-12 21:02:13 +0100210config DM_BIO_PRISON
211 tristate
Alasdair G Kergond57916a2013-03-01 22:45:46 +0000212 depends on BLK_DEV_DM
Mike Snitzer4f81a412012-10-12 21:02:13 +0100213 ---help---
214 Some bio locking schemes used by other device-mapper targets
215 including thin provisioning.
216
Joe Thornber991d9fa2011-10-31 20:21:18 +0000217source "drivers/md/persistent-data/Kconfig"
218
Linus Torvalds1da177e2005-04-16 15:20:36 -0700219config DM_CRYPT
220 tristate "Crypt target support"
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000221 depends on BLK_DEV_DM
Linus Torvalds1da177e2005-04-16 15:20:36 -0700222 select CRYPTO
Herbert Xu32632632006-12-10 09:50:36 +1100223 select CRYPTO_CBC
Linus Torvalds1da177e2005-04-16 15:20:36 -0700224 ---help---
225 This device-mapper target allows you to create a device that
226 transparently encrypts the data on it. You'll need to activate
227 the ciphers you're going to use in the cryptoapi configuration.
228
229 Information on how to use dm-crypt can be found on
230
231 <http://www.saout.de/misc/dm-crypt/>
232
233 To compile this code as a module, choose M here: the module will
234 be called dm-crypt.
235
236 If unsure, say N.
237
238config DM_SNAPSHOT
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000239 tristate "Snapshot target"
240 depends on BLK_DEV_DM
Linus Torvalds1da177e2005-04-16 15:20:36 -0700241 ---help---
Justin Piszcz4d2554d2006-06-26 00:27:50 -0700242 Allow volume managers to take writable snapshots of a device.
Linus Torvalds1da177e2005-04-16 15:20:36 -0700243
Joe Thornber991d9fa2011-10-31 20:21:18 +0000244config DM_THIN_PROVISIONING
Alasdair G Kergond57916a2013-03-01 22:45:46 +0000245 tristate "Thin provisioning target"
246 depends on BLK_DEV_DM
Joe Thornber991d9fa2011-10-31 20:21:18 +0000247 select DM_PERSISTENT_DATA
Mike Snitzer4f81a412012-10-12 21:02:13 +0100248 select DM_BIO_PRISON
Joe Thornber991d9fa2011-10-31 20:21:18 +0000249 ---help---
250 Provides thin provisioning and snapshots that share a data store.
251
252config DM_DEBUG_BLOCK_STACK_TRACING
253 boolean "Keep stack trace of thin provisioning block lock holders"
254 depends on STACKTRACE_SUPPORT && DM_THIN_PROVISIONING
255 select STACKTRACE
256 ---help---
257 Enable this for messages that may help debug problems with the
258 block manager locking used by thin provisioning.
259
260 If unsure, say N.
261
Joe Thornberc6b4fcb2013-03-01 22:45:51 +0000262config DM_CACHE
263 tristate "Cache target (EXPERIMENTAL)"
264 depends on BLK_DEV_DM
265 default n
266 select DM_PERSISTENT_DATA
267 select DM_BIO_PRISON
268 ---help---
269 dm-cache attempts to improve performance of a block device by
270 moving frequently used data to a smaller, higher performance
271 device. Different 'policy' plugins can be used to change the
272 algorithms used to select which blocks are promoted, demoted,
273 cleaned etc. It supports writeback and writethrough modes.
274
Joe Thornberf2836352013-03-01 22:45:51 +0000275config DM_CACHE_MQ
276 tristate "MQ Cache Policy (EXPERIMENTAL)"
277 depends on DM_CACHE
278 default y
279 ---help---
280 A cache policy that uses a multiqueue ordered by recent hit
281 count to select which blocks should be promoted and demoted.
282 This is meant to be a general purpose policy. It prioritises
283 reads over writes.
284
Heinz Mauelshagen8735a812013-03-01 22:45:52 +0000285config DM_CACHE_CLEANER
286 tristate "Cleaner Cache Policy (EXPERIMENTAL)"
287 depends on DM_CACHE
288 default y
289 ---help---
290 A simple cache policy that writes back all data to the
291 origin. Used when decommissioning a dm-cache.
292
Linus Torvalds1da177e2005-04-16 15:20:36 -0700293config DM_MIRROR
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000294 tristate "Mirror target"
295 depends on BLK_DEV_DM
Linus Torvalds1da177e2005-04-16 15:20:36 -0700296 ---help---
297 Allow volume managers to mirror logical volumes, also
298 needed for live data migration tools such as 'pvmove'.
299
NeilBrown9d09e662011-01-13 20:00:02 +0000300config DM_RAID
NeilBrownd9f691c2012-08-02 08:35:43 +1000301 tristate "RAID 1/4/5/6/10 target"
Alasdair G Kergon035220b2012-03-28 18:41:24 +0100302 depends on BLK_DEV_DM
Jonathan Brassowb12d4372011-08-02 12:32:07 +0100303 select MD_RAID1
NeilBrownd9f691c2012-08-02 08:35:43 +1000304 select MD_RAID10
NeilBrown9d09e662011-01-13 20:00:02 +0000305 select MD_RAID456
306 select BLK_DEV_MD
307 ---help---
NeilBrownd9f691c2012-08-02 08:35:43 +1000308 A dm target that supports RAID1, RAID10, RAID4, RAID5 and RAID6 mappings
NeilBrown9d09e662011-01-13 20:00:02 +0000309
310 A RAID-5 set of N drives with a capacity of C MB per drive provides
311 the capacity of C * (N - 1) MB, and protects against a failure
312 of a single drive. For a given sector (row) number, (N - 1) drives
313 contain data sectors, and one drive contains the parity protection.
314 For a RAID-4 set, the parity blocks are present on a single drive,
315 while a RAID-5 set distributes the parity across the drives in one
316 of the available parity distribution methods.
317
318 A RAID-6 set of N drives with a capacity of C MB per drive
319 provides the capacity of C * (N - 2) MB, and protects
320 against a failure of any two drives. For a given sector
321 (row) number, (N - 2) drives contain data sectors, and two
322 drives contains two independent redundancy syndromes. Like
323 RAID-5, RAID-6 distributes the syndromes across the drives
324 in one of the available parity distribution methods.
325
Jonthan Brassowf5db4af2009-06-22 10:12:35 +0100326config DM_LOG_USERSPACE
Alasdair G Kergond57916a2013-03-01 22:45:46 +0000327 tristate "Mirror userspace logging"
328 depends on DM_MIRROR && NET
Jonthan Brassowf5db4af2009-06-22 10:12:35 +0100329 select CONNECTOR
330 ---help---
331 The userspace logging module provides a mechanism for
332 relaying the dm-dirty-log API to userspace. Log designs
333 which are more suited to userspace implementation (e.g.
334 shared storage logs) or experimental logs can be implemented
335 by leveraging this framework.
336
Linus Torvalds1da177e2005-04-16 15:20:36 -0700337config DM_ZERO
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000338 tristate "Zero target"
339 depends on BLK_DEV_DM
Linus Torvalds1da177e2005-04-16 15:20:36 -0700340 ---help---
341 A target that discards writes, and returns all zeroes for
342 reads. Useful in some recovery situations.
343
344config DM_MULTIPATH
Alasdair G Kergon0149e572008-02-08 02:10:32 +0000345 tristate "Multipath target"
346 depends on BLK_DEV_DM
Chandra Seetharamanfe9233f2008-05-23 18:16:40 -0700347 # nasty syntax but means make DM_MULTIPATH independent
348 # of SCSI_DH if the latter isn't defined but if
349 # it is, DM_MULTIPATH must depend on it. We get a build
350 # error if SCSI_DH=m and DM_MULTIPATH=y
351 depends on SCSI_DH || !SCSI_DH
Linus Torvalds1da177e2005-04-16 15:20:36 -0700352 ---help---
353 Allow volume managers to support multipath hardware.
354
Kiyoshi Uedafd5e0332009-06-22 10:12:27 +0100355config DM_MULTIPATH_QL
356 tristate "I/O Path Selector based on the number of in-flight I/Os"
357 depends on DM_MULTIPATH
358 ---help---
359 This path selector is a dynamic load balancer which selects
360 the path with the least number of in-flight I/Os.
361
362 If unsure, say N.
363
Kiyoshi Uedaf392ba82009-06-22 10:12:28 +0100364config DM_MULTIPATH_ST
365 tristate "I/O Path Selector based on the service time"
366 depends on DM_MULTIPATH
367 ---help---
368 This path selector is a dynamic load balancer which selects
369 the path expected to complete the incoming I/O in the shortest
370 time.
371
372 If unsure, say N.
373
Heinz Mauelshagen26b9f222007-05-09 02:33:06 -0700374config DM_DELAY
Alasdair G Kergond57916a2013-03-01 22:45:46 +0000375 tristate "I/O delaying target"
376 depends on BLK_DEV_DM
Heinz Mauelshagen26b9f222007-05-09 02:33:06 -0700377 ---help---
378 A target that delays reads and/or writes and can send
379 them to different devices. Useful for testing.
380
381 If unsure, say N.
382
Mike Anderson51e5b2b2007-10-19 22:48:00 +0100383config DM_UEVENT
Alasdair G Kergone0b215d2012-03-28 18:41:24 +0100384 bool "DM uevents"
385 depends on BLK_DEV_DM
Mike Anderson51e5b2b2007-10-19 22:48:00 +0100386 ---help---
387 Generate udev events for DM events.
388
Josef Bacik3407ef52011-03-24 13:54:24 +0000389config DM_FLAKEY
Alasdair G Kergond57916a2013-03-01 22:45:46 +0000390 tristate "Flakey target"
391 depends on BLK_DEV_DM
Josef Bacik3407ef52011-03-24 13:54:24 +0000392 ---help---
393 A target that intermittently fails I/O for debugging purposes.
394
Mikulas Patockaa4ffc152012-03-28 18:43:38 +0100395config DM_VERITY
Alasdair G Kergond57916a2013-03-01 22:45:46 +0000396 tristate "Verity target support"
397 depends on BLK_DEV_DM
Mikulas Patockaa4ffc152012-03-28 18:43:38 +0100398 select CRYPTO
399 select CRYPTO_HASH
400 select DM_BUFIO
401 ---help---
402 This device-mapper target creates a read-only device that
403 transparently validates the data on one underlying device against
404 a pre-generated tree of cryptographic checksums stored on a second
405 device.
406
407 You'll need to activate the digests you're going to use in the
408 cryptoapi configuration.
409
410 To compile this code as a module, choose M here: the module will
411 be called dm-verity.
412
413 If unsure, say N.
414
Jim Ramsay9d0eb0a2013-07-10 23:41:19 +0100415config DM_SWITCH
416 tristate "Switch target support (EXPERIMENTAL)"
417 depends on BLK_DEV_DM
418 ---help---
419 This device-mapper target creates a device that supports an arbitrary
420 mapping of fixed-size regions of I/O across a fixed set of paths.
421 The path used for any specific region can be switched dynamically
422 by sending the target a message.
423
424 To compile this code as a module, choose M here: the module will
425 be called dm-switch.
426
427 If unsure, say N.
428