Input: s3c2410_ts - fix preparing/enabling clock
Use clk_prepare_enable/clk_disable_unprepare to make the driver
work properly with common clock framework.
Signed-off-by: Vasily Khoruzhick <anarsoul@gmail.com>
Reviewed-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
diff --git a/drivers/input/touchscreen/s3c2410_ts.c b/drivers/input/touchscreen/s3c2410_ts.c
index 19cb247..5a69ded 100644
--- a/drivers/input/touchscreen/s3c2410_ts.c
+++ b/drivers/input/touchscreen/s3c2410_ts.c
@@ -264,7 +264,7 @@
return -ENOENT;
}
- clk_enable(ts.clock);
+ clk_prepare_enable(ts.clock);
dev_dbg(dev, "got and enabled clocks\n");
ts.irq_tc = ret = platform_get_irq(pdev, 0);
@@ -369,7 +369,7 @@
free_irq(ts.irq_tc, ts.input);
del_timer_sync(&touch_timer);
- clk_disable(ts.clock);
+ clk_disable_unprepare(ts.clock);
clk_put(ts.clock);
input_unregister_device(ts.input);