usb: trival: Fix debugging units mistake.

SEL and PEL are in microseconds, not milliseconds.  Also, fix a split
string that will trigger checkpatch warnings.

Signed-off-by: Sarah Sharp <sarah.a.sharp@linux.intel.com>
diff --git a/drivers/usb/core/hub.c b/drivers/usb/core/hub.c
index b8e11ff..64854d7 100644
--- a/drivers/usb/core/hub.c
+++ b/drivers/usb/core/hub.c
@@ -3241,8 +3241,7 @@
 			(state == USB3_LPM_U2 &&
 			 (u2_sel > USB3_LPM_MAX_U2_SEL_PEL ||
 			  u2_pel > USB3_LPM_MAX_U2_SEL_PEL))) {
-		dev_dbg(&udev->dev, "Device-initiated %s disabled due "
-				"to long SEL %llu ms or PEL %llu ms\n",
+		dev_dbg(&udev->dev, "Device-initiated %s disabled due to long SEL %llu us or PEL %llu us\n",
 				usb3_lpm_names[state], u1_sel, u1_pel);
 		return -EINVAL;
 	}