hwmon: (lm90) Support ADT7461 in extended mode

Support ADT7461 in extended temperature range mode, which will change
the range of readings from 0..127 to -64..191 degC.  Adjust the
register conversion functions accordingly.

Signed-off-by: Nate Case <ncase@xes-inc.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Tested-by: Martyn Welch <martyn.welch@gefanuc.com>
3 files changed