lis3: introduce platform data for second ff / wu unit

8 bit device has two wakeup / free fall units.  It was not possible to
configure the second unit.  This patch introduces configuration entry to
the platform data and also corresponding changes to the 8 bit setup
function.

High pass filters were enabled by default.  Patch introduces configuration
option for high pass filter cut off frequency and also possibility to
disable or enable the filter via platform data.  Since the control is a
new one and default state was filter enabled, new option is used to
disable the filter.  This way old platform data is still compatible with
the change.

Signed-off-by: Samu Onkalo <samu.p.onkalo@nokia.com>
Acked-by: Eric Piel <eric.piel@tremplin-utc.net>
Tested-by: Daniel Mack <daniel@caiaq.de>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2 files changed