be2net: Prevent VFs from enabling VLAN promiscuous mode

Currently, a PF does not restrict its VF interface from enabling vlan
promiscuous mode. This breaks vlan isolation when a vlan
(transparent tagging) is configured on a VF.

This patch fixes this problem by disabling the vlan promisc capability
for VFs.

Reported-by: Yoann Juet <veilletechno-irts@univ-nantes.fr>
Signed-off-by: Vasundhara Volam <vasundhara.volam@emulex.com>
Signed-off-by: Sathya Perla <sathya.perla@emulex.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/ethernet/emulex/benet/be_cmds.c b/drivers/net/ethernet/emulex/benet/be_cmds.c
index 36916cf..3e894f4 100644
--- a/drivers/net/ethernet/emulex/benet/be_cmds.c
+++ b/drivers/net/ethernet/emulex/benet/be_cmds.c
@@ -1918,7 +1918,7 @@
 
 /* Uses sycnhronous mcc */
 int be_cmd_vlan_config(struct be_adapter *adapter, u32 if_id, u16 *vtag_array,
-		       u32 num)
+		       u32 num, u32 domain)
 {
 	struct be_mcc_wrb *wrb;
 	struct be_cmd_req_vlan_config *req;
@@ -1936,6 +1936,7 @@
 	be_wrb_cmd_hdr_prepare(&req->hdr, CMD_SUBSYSTEM_COMMON,
 			       OPCODE_COMMON_NTWK_VLAN_CONFIG, sizeof(*req),
 			       wrb, NULL);
+	req->hdr.domain = domain;
 
 	req->interface_id = if_id;
 	req->untagged = BE_IF_FLAGS_UNTAGGED & be_if_cap_flags(adapter) ? 1 : 0;