sound: oxygen: fix input monitor control names
Insert "Playback" into the input monitor control names to prevent
alsa-lib from treating these controls as global controls.
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
diff --git a/sound/pci/oxygen/oxygen_mixer.c b/sound/pci/oxygen/oxygen_mixer.c
index 5dfb5fb..f375b8a 100644
--- a/sound/pci/oxygen/oxygen_mixer.c
+++ b/sound/pci/oxygen/oxygen_mixer.c
@@ -805,7 +805,7 @@
.controls = {
{
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
- .name = "Analog Input Monitor Switch",
+ .name = "Analog Input Monitor Playback Switch",
.info = snd_ctl_boolean_mono_info,
.get = monitor_get,
.put = monitor_put,
@@ -813,7 +813,7 @@
},
{
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
- .name = "Analog Input Monitor Volume",
+ .name = "Analog Input Monitor Playback Volume",
.access = SNDRV_CTL_ELEM_ACCESS_READWRITE |
SNDRV_CTL_ELEM_ACCESS_TLV_READ,
.info = monitor_volume_info,
@@ -830,7 +830,7 @@
.controls = {
{
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
- .name = "Analog Input Monitor Switch",
+ .name = "Analog Input Monitor Playback Switch",
.info = snd_ctl_boolean_mono_info,
.get = monitor_get,
.put = monitor_put,
@@ -838,7 +838,7 @@
},
{
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
- .name = "Analog Input Monitor Volume",
+ .name = "Analog Input Monitor Playback Volume",
.access = SNDRV_CTL_ELEM_ACCESS_READWRITE |
SNDRV_CTL_ELEM_ACCESS_TLV_READ,
.info = monitor_volume_info,
@@ -855,7 +855,7 @@
.controls = {
{
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
- .name = "Analog Input Monitor Switch",
+ .name = "Analog Input Monitor Playback Switch",
.index = 1,
.info = snd_ctl_boolean_mono_info,
.get = monitor_get,
@@ -864,7 +864,7 @@
},
{
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
- .name = "Analog Input Monitor Volume",
+ .name = "Analog Input Monitor Playback Volume",
.index = 1,
.access = SNDRV_CTL_ELEM_ACCESS_READWRITE |
SNDRV_CTL_ELEM_ACCESS_TLV_READ,
@@ -882,7 +882,7 @@
.controls = {
{
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
- .name = "Digital Input Monitor Switch",
+ .name = "Digital Input Monitor Playback Switch",
.info = snd_ctl_boolean_mono_info,
.get = monitor_get,
.put = monitor_put,
@@ -890,7 +890,7 @@
},
{
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
- .name = "Digital Input Monitor Volume",
+ .name = "Digital Input Monitor Playback Volume",
.access = SNDRV_CTL_ELEM_ACCESS_READWRITE |
SNDRV_CTL_ELEM_ACCESS_TLV_READ,