[media] coda: reset CODA960 hardware after sequence end

On i.MX6, sometimes after decoding a stream, encoding will produce macroblock
errors caused by missing 8-byte sequences in the output stream. Until the cause
for this is found, reset the hardware after sequence end, which seems to help.

Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
diff --git a/drivers/media/platform/coda/coda-bit.c b/drivers/media/platform/coda/coda-bit.c
index 25910cc..bcb9911 100644
--- a/drivers/media/platform/coda/coda-bit.c
+++ b/drivers/media/platform/coda/coda-bit.c
@@ -1347,6 +1347,14 @@
 			 "CODA_COMMAND_SEQ_END failed\n");
 	}
 
+	/*
+	 * FIXME: Sometimes h.264 encoding fails with 8-byte sequences missing
+	 * from the output stream after the h.264 decoder has run. Resetting the
+	 * hardware after the decoder has finished seems to help.
+	 */
+	if (dev->devtype->product == CODA_960)
+		coda_hw_reset(ctx);
+
 	kfifo_init(&ctx->bitstream_fifo,
 		ctx->bitstream.vaddr, ctx->bitstream.size);