| * Copyright (C) ST-Ericsson SA 2011 |
| * |
| * License Terms: GNU General Public License v2 |
| * Author: Mattias Wallin <mattias.wallin@stericsson.com> for ST-Ericsson |
| */ |
| #include <linux/io.h> |
| #include <linux/errno.h> |
| #include <linux/clksrc-dbx500-prcmu.h> |
| #include <linux/clocksource.h> |
| #include <linux/of.h> |
| #include <linux/of_address.h> |
| #include <linux/platform_data/clocksource-nomadik-mtu.h> |
| |
| #include <asm/smp_twd.h> |
| |
| #include "setup.h" |
| #include "irqs.h" |
| |
| #include "db8500-regs.h" |
| #include "id.h" |
| |
| #ifdef CONFIG_HAVE_ARM_TWD |
| static DEFINE_TWD_LOCAL_TIMER(u8500_twd_local_timer, |
| U8500_TWD_BASE, IRQ_LOCALTIMER); |
| |
| static void __init ux500_twd_init(void) |
| { |
| struct twd_local_timer *twd_local_timer; |
| int err; |
| |
| /* Use this to switch local timer base if changed in new ASICs */ |
| twd_local_timer = &u8500_twd_local_timer; |
| |
| if (of_have_populated_dt()) |
| clocksource_of_init(); |
| else { |
| err = twd_local_timer_register(twd_local_timer); |
| if (err) |
| pr_err("twd_local_timer_register failed %d\n", err); |
| } |
| } |
| #else |
| #define ux500_twd_init() do { } while(0) |
| #endif |
| |
| const static struct of_device_id prcmu_timer_of_match[] __initconst = { |
| { .compatible = "stericsson,db8500-prcmu-timer-4", }, |
| { }, |
| }; |
| |
| void __init ux500_timer_init(void) |
| { |
| void __iomem *mtu_timer_base; |
| void __iomem *prcmu_timer_base; |
| void __iomem *tmp_base; |
| struct device_node *np; |
| |
| if (cpu_is_u8500_family() || cpu_is_ux540_family()) { |
| mtu_timer_base = __io_address(U8500_MTU0_BASE); |
| prcmu_timer_base = __io_address(U8500_PRCMU_TIMER_4_BASE); |
| } else { |
| ux500_unknown_soc(); |
| } |
| |
| /* TODO: Once MTU has been DT:ed place code above into else. */ |
| if (of_have_populated_dt()) { |
| #ifdef CONFIG_OF |
| np = of_find_matching_node(NULL, prcmu_timer_of_match); |
| if (!np) |
| #endif |
| goto dt_fail; |
| |
| tmp_base = of_iomap(np, 0); |
| if (!tmp_base) |
| goto dt_fail; |
| |
| prcmu_timer_base = tmp_base; |
| } |
| |
| dt_fail: |
| /* Doing it the old fashioned way. */ |
| |
| /* |
| * Here we register the timerblocks active in the system. |
| * Localtimers (twd) is started when both cpu is up and running. |
| * MTU register a clocksource, clockevent and sched_clock. |
| * Since the MTU is located in the VAPE power domain |
| * it will be cleared in sleep which makes it unsuitable. |
| * We however need it as a timer tick (clockevent) |
| * during boot to calibrate delay until twd is started. |
| * RTC-RTT have problems as timer tick during boot since it is |
| * depending on delay which is not yet calibrated. RTC-RTT is in the |
| * always-on powerdomain and is used as clockevent instead of twd when |
| * sleeping. |
| * The PRCMU timer 4 register a clocksource and |
| * sched_clock with higher rating then MTU since is always-on. |
| * |
| */ |
| if (!of_have_populated_dt()) |
| nmdk_timer_init(mtu_timer_base, IRQ_MTU0); |
| clksrc_dbx500_prcmu_init(prcmu_timer_base); |
| ux500_twd_init(); |
| } |