[PATCH] w1: real fix for big endian machines.

Real fix for big endian machines - crc must be calculated
using little endian byte order.

Signed-off-by: Evgeniy Polyakov <johnpol@2ka.mipt.ru>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>


1 file changed