commit | 91bba688016be0ba87ecb9d80d6490c2ebc63b0d | [log] [tgz] |
---|---|---|
author | Guenter Roeck <linux@roeck-us.net> | Thu Jan 10 21:16:47 2013 -0800 |
committer | Guenter Roeck <linux@roeck-us.net> | Wed Feb 06 09:57:57 2013 -0800 |
tree | f16bbaa5947f88b590f73ff3fb0719610637c475 | |
parent | b06367070de3d9f50e4f8f82b92e77ba9a8ebf8f [diff] |
hwmon: (lm73) Fix lower and upper temperature limits While the LM73 is only specified for temperatures from -40 to +150 degrees C, its power-up minimum and maximum temperature limits are -256 and +255.75 degrees C. For better consistency and to avoid confusion, clamp limits to the power-up limits and not to -40 / +150 degrees C. Signed-off-by: Guenter Roeck <linux@roeck-us.net>