omap_hsmmc: do not re-power when powering off MMC
Remove code that turns MMC1 power back on after it
has been powered off (when the voltage is 1.8V).
The offending code is not necessary because the
host controller bus voltage is initialized to
3V when probing or resuming. Note that MMC powers up
with the highest voltage available (see mmc_power_up())
which will be 3V also.
Signed-off-by: Adrian Hunter <ext-adrian.hunter@nokia.com>
Acked-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Pierre Ossman <drzeus@drzeus.cx>
diff --git a/drivers/mmc/host/omap_hsmmc.c b/drivers/mmc/host/omap_hsmmc.c
index a631c81..303a797 100644
--- a/drivers/mmc/host/omap_hsmmc.c
+++ b/drivers/mmc/host/omap_hsmmc.c
@@ -485,9 +485,6 @@
u32 reg_val = 0;
int ret;
- if (host->id != OMAP_MMC1_DEVID)
- return 0;
-
/* Disable the clocks */
clk_disable(host->fclk);
clk_disable(host->iclk);
@@ -786,20 +783,6 @@
switch (ios->power_mode) {
case MMC_POWER_OFF:
mmc_slot(host).set_power(host->dev, host->slot_id, 0, 0);
- /*
- * Reset interface voltage to 3V if it's 1.8V now;
- * only relevant on MMC-1, the others always use 1.8V.
- *
- * REVISIT: If we are able to detect cards after unplugging
- * a 1.8V card, this code should not be needed.
- */
- if (host->id != OMAP_MMC1_DEVID)
- break;
- if (!(OMAP_HSMMC_READ(host->base, HCTL) & SDVSDET)) {
- int vdd = fls(host->mmc->ocr_avail) - 1;
- if (omap_mmc_switch_opcond(host, vdd) != 0)
- host->mmc->ios.vdd = vdd;
- }
break;
case MMC_POWER_UP:
mmc_slot(host).set_power(host->dev, host->slot_id, 1, ios->vdd);