net: ethernet: mediatek: remove superfluous local variable for phy address

remove the unused variable for parsing PHY address
and the related logic for sanity test which would
be all already handled done when of_mdiobus_register
was called

Reported-by: Nelson Chang <nelson.chang@mediatek.com>
Signed-off-by: Sean Wang <sean.wang@mediatek.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/ethernet/mediatek/mtk_eth_soc.c b/drivers/net/ethernet/mediatek/mtk_eth_soc.c
index 6b7acf4..1918c39 100644
--- a/drivers/net/ethernet/mediatek/mtk_eth_soc.c
+++ b/drivers/net/ethernet/mediatek/mtk_eth_soc.c
@@ -226,17 +226,9 @@
 static int mtk_phy_connect_node(struct mtk_eth *eth, struct mtk_mac *mac,
 				struct device_node *phy_node)
 {
-	const __be32 *_addr = NULL;
 	struct phy_device *phydev;
-	int phy_mode, addr;
+	int phy_mode;
 
-	_addr = of_get_property(phy_node, "reg", NULL);
-
-	if (!_addr || (be32_to_cpu(*_addr) >= 0x20)) {
-		pr_err("%s: invalid phy address\n", phy_node->name);
-		return -EINVAL;
-	}
-	addr = be32_to_cpu(*_addr);
 	phy_mode = of_get_phy_mode(phy_node);
 	if (phy_mode < 0) {
 		dev_err(eth->dev, "incorrect phy-mode %d\n", phy_mode);