charger-manager: Poll battery health in normal state
Charger-Manager needs to check battery health in normal state
as well as suspend-to-RAM state. When the battery is fully charged,
Charger-Manager needs to determine when the chargers restart charging.
This patch allows Charger-Manager to monitor battery health in normal
state and handle operation for chargers after battery is fully charged.
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
diff --git a/Documentation/power/charger-manager.txt b/Documentation/power/charger-manager.txt
index fdcca99..9b38633 100644
--- a/Documentation/power/charger-manager.txt
+++ b/Documentation/power/charger-manager.txt
@@ -44,6 +44,12 @@
Normally, the platform will need to resume and suspend some devices
that are used by Charger Manager.
+* Support for premature full-battery event handling
+ If the battery voltage drops by "fullbatt_vchkdrop_uV" after
+ "fullbatt_vchkdrop_ms" from the full-battery event, the framework
+ restarts charging. This check is also performed while suspended by
+ setting wakeup time accordingly and using suspend_again.
+
2. Global Charger-Manager Data related with suspend_again
========================================================
In order to setup Charger Manager with suspend-again feature
@@ -55,7 +61,7 @@
multiple instances of Charger Manager share the same charger_global_desc
and it will manage in-suspend monitoring for all instances of Charger Manager.
-The user needs to provide all the two entries properly in order to activate
+The user needs to provide all the three entries properly in order to activate
in-suspend monitoring:
struct charger_global_desc {
@@ -74,6 +80,11 @@
same struct. If there is any other wakeup source triggered the
wakeup, it should return false. If the "rtc" is the only wakeup
reason, it should return true.
+
+bool assume_timer_stops_in_suspend;
+ : if true, Charger Manager assumes that
+ the timer (CM uses jiffies as timer) stops during suspend. Then, CM
+ assumes that the suspend-duration is same as the alarm length.
};
3. How to setup suspend_again
@@ -111,6 +122,16 @@
CM_POLL_CHARGING_ONLY: poll this battery if and only if the
battery is being charged.
+unsigned int fullbatt_vchkdrop_ms;
+unsigned int fullbatt_vchkdrop_uV;
+ : If both have non-zero values, Charger Manager will check the
+ battery voltage drop fullbatt_vchkdrop_ms after the battery is fully
+ charged. If the voltage drop is over fullbatt_vchkdrop_uV, Charger
+ Manager will try to recharge the battery by disabling and enabling
+ chargers. Recharge with voltage drop condition only (without delay
+ condition) is needed to be implemented with hardware interrupts from
+ fuel gauges or charger devices/chips.
+
unsigned int fullbatt_uV;
: If specified with a non-zero value, Charger Manager assumes
that the battery is full (capacity = 100) if the battery is not being
@@ -122,6 +143,8 @@
this battery every polling_interval_ms or more frequently.
enum data_source battery_present;
+ : CM_BATTERY_PRESENT: assume that the battery exists.
+ CM_NO_BATTERY: assume that the battery does not exists.
CM_FUEL_GAUGE: get battery presence information from fuel gauge.
CM_CHARGER_STAT: get battery presence from chargers.