Blackfin: fix accidental reset in some boot modes

We read the SWRST (Software Reset) register to get at the last reset
state, and then we may configure the DOUBLE_FAULT bit to control behavior
when a double fault occurs.  But if the lower bits of the register is
already set (like UART boot mode on a BF54x), we inadvertently make the
system reset by writing to the SYSTEM_RESET field at the same time.  So
make sure the lower 4 bits are always cleared.

Signed-off-by: Sonic Zhang <sonic.zhang@analog.com>
Signed-off-by: Mike Frysinger <vapier@gentoo.org>
1 file changed