ar9170: fix bug in iq-auto calibration value calculation
This patch fixes a embarrassing bug which was introduced by:
"[PATCH] ar9170: implement frequency calibration for one-stage/openfw"
The phy_data variable initialization has to done outside the for-loop
scope. This is because the for-loop uses u32 phy_data variable more
like a 4-byte field. But in each run only a single byte is calculated.
Therefore phy_data content needs to stay the same for at least 3 more
iterations, before the complete set can be uploaded.
Reported-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Christian Lamparter <chunkeey@googlemail.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
diff --git a/drivers/net/wireless/ath/ar9170/phy.c b/drivers/net/wireless/ath/ar9170/phy.c
index b3e5cf3..dbd488d 100644
--- a/drivers/net/wireless/ath/ar9170/phy.c
+++ b/drivers/net/wireless/ath/ar9170/phy.c
@@ -1141,7 +1141,8 @@
u8 vpds[2][AR5416_PD_GAIN_ICEPTS];
u8 pwrs[2][AR5416_PD_GAIN_ICEPTS];
int chain, idx, i;
- u8 f;
+ u32 phy_data = 0;
+ u8 f, tmp;
switch (channel->band) {
case IEEE80211_BAND_2GHZ:
@@ -1208,9 +1209,6 @@
}
for (i = 0; i < 76; i++) {
- u32 phy_data;
- u8 tmp;
-
if (i < 25) {
tmp = ar9170_interpolate_val(i, &pwrs[0][0],
&vpds[0][0]);