[PATCH] e1000: Fix flow control water marks
Fixed flow control water marks based on PBA size.
Store flow control state in original_fc in addition to fc.
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: Jesse Brandeburg <jesse.brandeburg@intel.com>
Signed-off-by: John Ronciak <john.ronciak@intel.com>
Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
diff --git a/drivers/net/e1000/e1000_param.c b/drivers/net/e1000/e1000_param.c
index b0be7d6..133a76b 100644
--- a/drivers/net/e1000/e1000_param.c
+++ b/drivers/net/e1000/e1000_param.c
@@ -388,7 +388,7 @@
e1000_validate_option(&fc, &opt, adapter);
adapter->hw.fc = adapter->hw.original_fc = fc;
} else {
- adapter->hw.fc = opt.def;
+ adapter->hw.fc = adapter->hw.original_fc = opt.def;
}
}
{ /* Transmit Interrupt Delay */