spi/dw_spi: remove conditional from 'poll_transfer'.

The 'poll_transfer' function employs a conditional to test whether the
transmit buffer is valid; in doing so, on a receive operation no data is
clocked out, thus no data is clocked in and ultimately errors appear.

This removes the conditional as the transmit function will be set to a null
writer when the transmit buffer is invalid, allowing the driver to clock
0x00 out to the device to receive data from the device.

Signed-off-by: George Shore <george@georgeshore.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
diff --git a/drivers/spi/dw_spi.c b/drivers/spi/dw_spi.c
index d0a080a..3853df5 100644
--- a/drivers/spi/dw_spi.c
+++ b/drivers/spi/dw_spi.c
@@ -408,12 +408,9 @@
 /* Must be called inside pump_transfers() */
 static void poll_transfer(struct dw_spi *dws)
 {
-	if (dws->tx) {
-		while (dws->write(dws))
-			dws->read(dws);
-	}
+	while (dws->write(dws))
+		dws->read(dws);
 
-	dws->read(dws);
 	transfer_complete(dws);
 }