| * at91sam926x_time.c - Periodic Interval Timer (PIT) for at91sam926x |
| * |
| * Copyright (C) 2005-2006 M. Amine SAYA, ATMEL Rousset, France |
| * Revision 2005 M. Nicolas Diremdjian, ATMEL Rousset, France |
| * Converted to ClockSource/ClockEvents by David Brownell. |
| * |
| * This program is free software; you can redistribute it and/or modify |
| * it under the terms of the GNU General Public License version 2 as |
| * published by the Free Software Foundation. |
| */ |
| #include <linux/interrupt.h> |
| #include <linux/irq.h> |
| #include <linux/kernel.h> |
| #include <linux/clk.h> |
| #include <linux/clockchips.h> |
| |
| #include <asm/mach/time.h> |
| |
| #include <mach/at91_pit.h> |
| |
| |
| #define PIT_CPIV(x) ((x) & AT91_PIT_CPIV) |
| #define PIT_PICNT(x) (((x) & AT91_PIT_PICNT) >> 20) |
| |
| static u32 pit_cycle; /* write-once */ |
| static u32 pit_cnt; /* access only w/system irq blocked */ |
| |
| |
| /* |
| * Clocksource: just a monotonic counter of MCK/16 cycles. |
| * We don't care whether or not PIT irqs are enabled. |
| */ |
| static cycle_t read_pit_clk(void) |
| { |
| unsigned long flags; |
| u32 elapsed; |
| u32 t; |
| |
| raw_local_irq_save(flags); |
| elapsed = pit_cnt; |
| t = at91_sys_read(AT91_PIT_PIIR); |
| raw_local_irq_restore(flags); |
| |
| elapsed += PIT_PICNT(t) * pit_cycle; |
| elapsed += PIT_CPIV(t); |
| return elapsed; |
| } |
| |
| static struct clocksource pit_clk = { |
| .name = "pit", |
| .rating = 175, |
| .read = read_pit_clk, |
| .shift = 20, |
| .flags = CLOCK_SOURCE_IS_CONTINUOUS, |
| }; |
| |
| |
| /* |
| * Clockevent device: interrupts every 1/HZ (== pit_cycles * MCK/16) |
| */ |
| static void |
| pit_clkevt_mode(enum clock_event_mode mode, struct clock_event_device *dev) |
| { |
| unsigned long flags; |
| |
| switch (mode) { |
| case CLOCK_EVT_MODE_PERIODIC: |
| /* update clocksource counter, then enable the IRQ */ |
| raw_local_irq_save(flags); |
| pit_cnt += pit_cycle * PIT_PICNT(at91_sys_read(AT91_PIT_PIVR)); |
| at91_sys_write(AT91_PIT_MR, (pit_cycle - 1) | AT91_PIT_PITEN |
| | AT91_PIT_PITIEN); |
| raw_local_irq_restore(flags); |
| break; |
| case CLOCK_EVT_MODE_ONESHOT: |
| BUG(); |
| /* FALLTHROUGH */ |
| case CLOCK_EVT_MODE_SHUTDOWN: |
| case CLOCK_EVT_MODE_UNUSED: |
| /* disable irq, leaving the clocksource active */ |
| at91_sys_write(AT91_PIT_MR, (pit_cycle - 1) | AT91_PIT_PITEN); |
| break; |
| case CLOCK_EVT_MODE_RESUME: |
| break; |
| } |
| } |
| |
| static struct clock_event_device pit_clkevt = { |
| .name = "pit", |
| .features = CLOCK_EVT_FEAT_PERIODIC, |
| .shift = 32, |
| .rating = 100, |
| .cpumask = CPU_MASK_CPU0, |
| .set_mode = pit_clkevt_mode, |
| }; |
| |
| |
| /* |
| * IRQ handler for the timer. |
| */ |
| static irqreturn_t at91sam926x_pit_interrupt(int irq, void *dev_id) |
| { |
| |
| /* The PIT interrupt may be disabled, and is shared */ |
| if ((pit_clkevt.mode == CLOCK_EVT_MODE_PERIODIC) |
| && (at91_sys_read(AT91_PIT_SR) & AT91_PIT_PITS)) { |
| unsigned nr_ticks; |
| |
| /* Get number of ticks performed before irq, and ack it */ |
| nr_ticks = PIT_PICNT(at91_sys_read(AT91_PIT_PIVR)); |
| do { |
| pit_cnt += pit_cycle; |
| pit_clkevt.event_handler(&pit_clkevt); |
| nr_ticks--; |
| } while (nr_ticks); |
| |
| return IRQ_HANDLED; |
| } |
| |
| return IRQ_NONE; |
| } |
| |
| static struct irqaction at91sam926x_pit_irq = { |
| .name = "at91_tick", |
| .flags = IRQF_SHARED | IRQF_DISABLED | IRQF_TIMER | IRQF_IRQPOLL, |
| .handler = at91sam926x_pit_interrupt |
| }; |
| |
| static void at91sam926x_pit_reset(void) |
| { |
| /* Disable timer and irqs */ |
| at91_sys_write(AT91_PIT_MR, 0); |
| |
| /* Clear any pending interrupts, wait for PIT to stop counting */ |
| while (PIT_CPIV(at91_sys_read(AT91_PIT_PIVR)) != 0) |
| cpu_relax(); |
| |
| /* Start PIT but don't enable IRQ */ |
| at91_sys_write(AT91_PIT_MR, (pit_cycle - 1) | AT91_PIT_PITEN); |
| } |
| |
| /* |
| * Set up both clocksource and clockevent support. |
| */ |
| static void __init at91sam926x_pit_init(void) |
| { |
| unsigned long pit_rate; |
| unsigned bits; |
| |
| /* |
| * Use our actual MCK to figure out how many MCK/16 ticks per |
| * 1/HZ period (instead of a compile-time constant LATCH). |
| */ |
| pit_rate = clk_get_rate(clk_get(NULL, "mck")) / 16; |
| pit_cycle = (pit_rate + HZ/2) / HZ; |
| WARN_ON(((pit_cycle - 1) & ~AT91_PIT_PIV) != 0); |
| |
| /* Initialize and enable the timer */ |
| at91sam926x_pit_reset(); |
| |
| /* |
| * Register clocksource. The high order bits of PIV are unused, |
| * so this isn't a 32-bit counter unless we get clockevent irqs. |
| */ |
| pit_clk.mult = clocksource_hz2mult(pit_rate, pit_clk.shift); |
| bits = 12 /* PICNT */ + ilog2(pit_cycle) /* PIV */; |
| pit_clk.mask = CLOCKSOURCE_MASK(bits); |
| clocksource_register(&pit_clk); |
| |
| /* Set up irq handler */ |
| setup_irq(AT91_ID_SYS, &at91sam926x_pit_irq); |
| |
| /* Set up and register clockevents */ |
| pit_clkevt.mult = div_sc(pit_rate, NSEC_PER_SEC, pit_clkevt.shift); |
| clockevents_register_device(&pit_clkevt); |
| } |
| |
| static void at91sam926x_pit_suspend(void) |
| { |
| /* Disable timer */ |
| at91_sys_write(AT91_PIT_MR, 0); |
| } |
| |
| struct sys_timer at91sam926x_timer = { |
| .init = at91sam926x_pit_init, |
| .suspend = at91sam926x_pit_suspend, |
| .resume = at91sam926x_pit_reset, |
| }; |