| * include/asm-s390/timex.h |
| * |
| * S390 version |
| * Copyright (C) 1999 IBM Deutschland Entwicklung GmbH, IBM Corporation |
| * |
| * Derived from "include/asm-i386/timex.h" |
| * Copyright (C) 1992, Linus Torvalds |
| */ |
| |
| #ifndef _ASM_S390_TIMEX_H |
| #define _ASM_S390_TIMEX_H |
| |
| /* The value of the TOD clock for 1.1.1970. */ |
| #define TOD_UNIX_EPOCH 0x7d91048bca000000ULL |
| |
| /* Inline functions for clock register access. */ |
| static inline int set_clock(__u64 time) |
| { |
| int cc; |
| |
| asm volatile( |
| " sck %1\n" |
| " ipm %0\n" |
| " srl %0,28\n" |
| : "=d" (cc) : "Q" (time) : "cc"); |
| return cc; |
| } |
| |
| static inline int store_clock(__u64 *time) |
| { |
| int cc; |
| |
| asm volatile( |
| " stck %1\n" |
| " ipm %0\n" |
| " srl %0,28\n" |
| : "=d" (cc), "=Q" (*time) : : "cc"); |
| return cc; |
| } |
| |
| static inline void set_clock_comparator(__u64 time) |
| { |
| asm volatile("sckc %0" : : "Q" (time)); |
| } |
| |
| static inline void store_clock_comparator(__u64 *time) |
| { |
| asm volatile("stckc %0" : "=Q" (*time)); |
| } |
| |
| #define CLOCK_TICK_RATE 1193180 /* Underlying HZ */ |
| |
| typedef unsigned long long cycles_t; |
| |
| static inline unsigned long long get_clock (void) |
| { |
| unsigned long long clk; |
| |
| asm volatile("stck %0" : "=Q" (clk) : : "cc"); |
| return clk; |
| } |
| |
| static inline unsigned long long get_clock_xt(void) |
| { |
| unsigned char clk[16]; |
| |
| asm volatile("stcke %0" : "=Q" (clk) : : "cc"); |
| return *((unsigned long long *)&clk[1]); |
| } |
| |
| static inline cycles_t get_cycles(void) |
| { |
| return (cycles_t) get_clock() >> 2; |
| } |
| |
| int get_sync_clock(unsigned long long *clock); |
| void init_cpu_timer(void); |
| unsigned long long monotonic_clock(void); |
| |
| void tod_to_timeval(__u64, struct timespec *); |
| |
| static inline |
| void stck_to_timespec(unsigned long long stck, struct timespec *ts) |
| { |
| tod_to_timeval(stck - TOD_UNIX_EPOCH, ts); |
| } |
| |
| extern u64 sched_clock_base_cc; |
| |
| /** |
| * get_clock_monotonic - returns current time in clock rate units |
| * |
| * The caller must ensure that preemption is disabled. |
| * The clock and sched_clock_base get changed via stop_machine. |
| * Therefore preemption must be disabled when calling this |
| * function, otherwise the returned value is not guaranteed to |
| * be monotonic. |
| */ |
| static inline unsigned long long get_clock_monotonic(void) |
| { |
| return get_clock_xt() - sched_clock_base_cc; |
| } |
| |
| #endif |