sched: Fix the irqtime code for 32bit

Since the irqtime accounting is using non-atomic u64 and can be read
from remote cpus (writes are strictly cpu local, reads are not) we
have to deal with observing partial updates.

When we do observe partial updates the clock movement (in particular,
->clock_task movement) will go funny (in either direction), a
subsequent clock update (observing the full update) will make it go
funny in the oposite direction.

Since we rely on these clocks to be strictly monotonic we cannot
suffer backwards motion. One possible solution would be to simply
ignore all backwards deltas, but that will lead to accounting
artefacts, most notable: clock_task + irq_time != clock, this
inaccuracy would end up in user visible stats.

Therefore serialize the reads using a seqcount.

Reviewed-by: Venkatesh Pallipadi <venki@google.com>
Reported-by: Mikael Pettersson <mikpe@it.uu.se>
Tested-by: Mikael Pettersson <mikpe@it.uu.se>
Signed-off-by: Peter Zijlstra <a.p.zijlstra@chello.nl>
LKML-Reference: <1292242434.6803.200.camel@twins>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
1 file changed