[SCSI] bnx2i: Fixed the TCP graceful termination initiation

In compliance to RFC793, a TCP graceful termination will be used
instead of an abortive termination for the case where the remote
has initiated the close of the connection.
Additionally, a TCP abortive termination will be used to close the
connection when a logout response is not received in time after a
logout request has been initiated.

Signed-off-by: Eddie Wai <eddie.wai@broadcom.com>
Reviewed-by: Michael Chan <mchan@broadcom.com>
Reviewed-by: Benjamin Li <benli@broadcom.com>
Acked-by: Anil Veerabhadrappa <anilgv@broadcom.com>
Reviewed-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>