sl82c105: convert to use ide_timing_find_mode()
There should be no functional changes caused by this patch.
Acked-by: Sergei Shtylyov <sshtylyov@ru.mvista.com>
Signed-off-by: Bartlomiej Zolnierkiewicz <bzolnier@gmail.com>
diff --git a/drivers/ide/Kconfig b/drivers/ide/Kconfig
index 7446db6..5f4d6ea 100644
--- a/drivers/ide/Kconfig
+++ b/drivers/ide/Kconfig
@@ -703,6 +703,7 @@
config BLK_DEV_SL82C105
tristate "Winbond SL82c105 support"
depends on (PPC || ARM)
+ select IDE_TIMINGS
select BLK_DEV_IDEDMA_PCI
help
If you have a Winbond SL82c105 IDE controller, say Y here to enable
diff --git a/drivers/ide/pci/sl82c105.c b/drivers/ide/pci/sl82c105.c
index ce84fa0..6efbde2 100644
--- a/drivers/ide/pci/sl82c105.c
+++ b/drivers/ide/pci/sl82c105.c
@@ -47,10 +47,11 @@
*/
static unsigned int get_pio_timings(ide_drive_t *drive, u8 pio)
{
+ struct ide_timing *t = ide_timing_find_mode(XFER_PIO_0 + pio);
unsigned int cmd_on, cmd_off;
u8 iordy = 0;
- cmd_on = (ide_pio_timings[pio].active_time + 29) / 30;
+ cmd_on = (t->active + 29) / 30;
cmd_off = (ide_pio_cycle_time(drive, pio) - 30 * cmd_on + 29) / 30;
if (cmd_on == 0)