[TG3]: Correct sw autoneg flow control advertisements

This patch modifies the software autoneg code to use the administrator
specified flow control parameters.  Since the autonegotiation code uses
alternative flow control enumerations, the 1000-BaseX utility functions
are used and code was added to convert the definitions to and from the
alternate enumerations.

Signed-off-by: Matt Carlson <mcarlson@broadcom.com>
Signed-off-by: Michael Chan <mchan@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/tg3.c b/drivers/net/tg3.c
index 3caead4..cdade05 100644
--- a/drivers/net/tg3.c
+++ b/drivers/net/tg3.c
@@ -1695,7 +1695,7 @@
 	u32 old_tx_mode = tp->tx_mode;
 
 	if (tp->tg3_flags & TG3_FLAG_PAUSE_AUTONEG) {
-		if (tp->tg3_flags2 & (TG3_FLG2_MII_SERDES|TG3_FLG2_HW_AUTONEG))
+		if (tp->tg3_flags2 & TG3_FLG2_ANY_SERDES)
 			new_tg3_flags = tg3_resolve_flowctrl_1000X(local_adv,
 								   remote_adv);
 		else
@@ -2317,6 +2317,7 @@
 static int tg3_fiber_aneg_smachine(struct tg3 *tp,
 				   struct tg3_fiber_aneginfo *ap)
 {
+	u16 flowctrl;
 	unsigned long delta;
 	u32 rx_cfg_reg;
 	int ret;
@@ -2416,7 +2417,12 @@
 
 	case ANEG_STATE_ABILITY_DETECT_INIT:
 		ap->flags &= ~(MR_TOGGLE_TX);
-		ap->txconfig = (ANEG_CFG_FD | ANEG_CFG_PS1);
+		ap->txconfig = ANEG_CFG_FD;
+		flowctrl = tg3_advert_flowctrl_1000X(tp->link_config.flowctrl);
+		if (flowctrl & ADVERTISE_1000XPAUSE)
+			ap->txconfig |= ANEG_CFG_PS1;
+		if (flowctrl & ADVERTISE_1000XPSE_ASYM)
+			ap->txconfig |= ANEG_CFG_PS2;
 		tw32(MAC_TX_AUTO_NEG, ap->txconfig);
 		tp->mac_mode |= MAC_MODE_SEND_CONFIGS;
 		tw32_f(MAC_MODE, tp->mac_mode);
@@ -2562,7 +2568,7 @@
 	return ret;
 }
 
-static int fiber_autoneg(struct tg3 *tp, u32 *flags)
+static int fiber_autoneg(struct tg3 *tp, u32 *txflags, u32 *rxflags)
 {
 	int res = 0;
 	struct tg3_fiber_aneginfo aninfo;
@@ -2596,7 +2602,8 @@
 	tw32_f(MAC_MODE, tp->mac_mode);
 	udelay(40);
 
-	*flags = aninfo.flags;
+	*txflags = aninfo.txconfig;
+	*rxflags = aninfo.flags;
 
 	if (status == ANEG_DONE &&
 	    (aninfo.flags & (MR_AN_COMPLETE | MR_LINK_OK |
@@ -2806,18 +2813,21 @@
 		goto out;
 
 	if (tp->link_config.autoneg == AUTONEG_ENABLE) {
-		u32 flags;
+		u32 txflags, rxflags;
 		int i;
 
-		if (fiber_autoneg(tp, &flags)) {
-			u32 local_adv, remote_adv;
+		if (fiber_autoneg(tp, &txflags, &rxflags)) {
+			u32 local_adv = 0, remote_adv = 0;
 
-			local_adv = ADVERTISE_PAUSE_CAP;
-			remote_adv = 0;
-			if (flags & MR_LP_ADV_SYM_PAUSE)
-				remote_adv |= LPA_PAUSE_CAP;
-			if (flags & MR_LP_ADV_ASYM_PAUSE)
-				remote_adv |= LPA_PAUSE_ASYM;
+			if (txflags & ANEG_CFG_PS1)
+				local_adv |= ADVERTISE_1000XPAUSE;
+			if (txflags & ANEG_CFG_PS2)
+				local_adv |= ADVERTISE_1000XPSE_ASYM;
+
+			if (rxflags & MR_LP_ADV_SYM_PAUSE)
+				remote_adv |= LPA_1000XPAUSE;
+			if (rxflags & MR_LP_ADV_ASYM_PAUSE)
+				remote_adv |= LPA_1000XPAUSE_ASYM;
 
 			tg3_setup_flow_control(tp, local_adv, remote_adv);
 
@@ -2841,6 +2851,8 @@
 		    !(mac_status & MAC_STATUS_RCVD_CFG))
 			current_link_up = 1;
 	} else {
+		tg3_setup_flow_control(tp, 0, 0);
+
 		/* Forcing 1000FD link up. */
 		current_link_up = 1;