msm: msm_bus: Correct bypass mode settings for BIMC masters

If a master is in fixed or bypass mode, it's bandwidth registers
should not be touched. Currently, the bus driver attempts to
configure bandwidth registers during init. This patch fixes
this error.

Change-Id: I49b2104f1c429ac5ea3fb4e8f692cb3dd363c3be
CRs-Fixed: 439869
Signed-off-by: Gagan Mac <gmac@codeaurora.org>
1 file changed