commit | 630f2f920e4d8f119d304cce3730dc469670234d | [log] [tgz] |
---|---|---|
author | Phani Kumar Uppalapati <phaniu@codeaurora.org> | Tue May 21 23:19:43 2013 -0700 |
committer | Phani Kumar Uppalapati <phaniu@codeaurora.org> | Wed May 22 12:43:33 2013 -0700 |
tree | c48c5c41812d2b7ff7400303668ce0ff18559880 | |
parent | a2aa7316c4c8df858e9d9fc9750288e8613a9e54 [diff] |
ASoC: wcd9xxx: Change Supply Switch Control to automatic On Tapan codec, supply voltage to the scaling_mux_1 register has to be set to automatic to be able to measure the mic voltage correctly when mic bias is pulled high above 2.2 Volts, so leave the register TX_SUP_SWITCH_CTRL_1 to default value of 0. Change-Id: I2c55c1b95f8fe769ea6c330963255b5f45270a2f Signed-off-by: Phani Kumar Uppalapati <phaniu@codeaurora.org>