| /* Copyright (c) 2012-2013, The Linux Foundation. All rights reserved. |
| * |
| * This program is free software; you can redistribute it and/or modify |
| * it under the terms of the GNU General Public License version 2 and |
| * only version 2 as published by the Free Software Foundation. |
| * |
| * This program is distributed in the hope that it will be useful, |
| * but WITHOUT ANY WARRANTY; without even the implied warranty of |
| * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the |
| * GNU General Public License for more details. |
| * |
| */ |
| |
| #include <linux/kernel.h> |
| #include <linux/init.h> |
| #include <linux/module.h> |
| #include <linux/mutex.h> |
| #include <linux/msm_tsens.h> |
| #include <linux/workqueue.h> |
| #include <linux/cpu.h> |
| #include <linux/cpufreq.h> |
| #include <linux/msm_tsens.h> |
| #include <linux/msm_thermal.h> |
| #include <linux/platform_device.h> |
| #include <linux/of.h> |
| #include <mach/cpufreq.h> |
| |
| static int enabled; |
| static struct msm_thermal_data msm_thermal_info; |
| static uint32_t limited_max_freq = MSM_CPUFREQ_NO_LIMIT; |
| static struct delayed_work check_temp_work; |
| |
| static int limit_idx; |
| static int limit_idx_low; |
| static int limit_idx_high; |
| static struct cpufreq_frequency_table *table; |
| |
| static int msm_thermal_get_freq_table(void) |
| { |
| int ret = 0; |
| int i = 0; |
| |
| table = cpufreq_frequency_get_table(0); |
| if (table == NULL) { |
| pr_debug("%s: error reading cpufreq table\n", __func__); |
| ret = -EINVAL; |
| goto fail; |
| } |
| |
| while (table[i].frequency != CPUFREQ_TABLE_END) |
| i++; |
| |
| limit_idx_low = 0; |
| limit_idx_high = limit_idx = i - 1; |
| BUG_ON(limit_idx_high <= 0 || limit_idx_high <= limit_idx_low); |
| fail: |
| return ret; |
| } |
| |
| static int update_cpu_max_freq(int cpu, uint32_t max_freq) |
| { |
| int ret = 0; |
| |
| ret = msm_cpufreq_set_freq_limits(cpu, MSM_CPUFREQ_NO_LIMIT, max_freq); |
| if (ret) |
| return ret; |
| |
| limited_max_freq = max_freq; |
| if (max_freq != MSM_CPUFREQ_NO_LIMIT) |
| pr_info("msm_thermal: Limiting cpu%d max frequency to %d\n", |
| cpu, max_freq); |
| else |
| pr_info("msm_thermal: Max frequency reset for cpu%d\n", cpu); |
| |
| ret = cpufreq_update_policy(cpu); |
| |
| return ret; |
| } |
| |
| static void check_temp(struct work_struct *work) |
| { |
| static int limit_init; |
| struct tsens_device tsens_dev; |
| long temp = 0; |
| uint32_t max_freq = limited_max_freq; |
| int cpu = 0; |
| int ret = 0; |
| |
| tsens_dev.sensor_num = msm_thermal_info.sensor_id; |
| ret = tsens_get_temp(&tsens_dev, &temp); |
| if (ret) { |
| pr_debug("msm_thermal: Unable to read TSENS sensor %d\n", |
| tsens_dev.sensor_num); |
| goto reschedule; |
| } |
| |
| if (!limit_init) { |
| ret = msm_thermal_get_freq_table(); |
| if (ret) |
| goto reschedule; |
| else |
| limit_init = 1; |
| } |
| |
| if (temp >= msm_thermal_info.limit_temp_degC) { |
| if (limit_idx == limit_idx_low) |
| goto reschedule; |
| |
| limit_idx -= msm_thermal_info.freq_step; |
| if (limit_idx < limit_idx_low) |
| limit_idx = limit_idx_low; |
| max_freq = table[limit_idx].frequency; |
| } else if (temp < msm_thermal_info.limit_temp_degC - |
| msm_thermal_info.temp_hysteresis_degC) { |
| if (limit_idx == limit_idx_high) |
| goto reschedule; |
| |
| limit_idx += msm_thermal_info.freq_step; |
| if (limit_idx >= limit_idx_high) { |
| limit_idx = limit_idx_high; |
| max_freq = MSM_CPUFREQ_NO_LIMIT; |
| } else |
| max_freq = table[limit_idx].frequency; |
| } |
| if (max_freq == limited_max_freq) |
| goto reschedule; |
| |
| /* Update new limits */ |
| for_each_possible_cpu(cpu) { |
| ret = update_cpu_max_freq(cpu, max_freq); |
| if (ret) |
| pr_debug("Unable to limit cpu%d max freq to %d\n", |
| cpu, max_freq); |
| } |
| |
| reschedule: |
| if (enabled) |
| schedule_delayed_work(&check_temp_work, |
| msecs_to_jiffies(msm_thermal_info.poll_ms)); |
| } |
| |
| static void disable_msm_thermal(void) |
| { |
| int cpu = 0; |
| |
| /* make sure check_temp is no longer running */ |
| cancel_delayed_work(&check_temp_work); |
| flush_scheduled_work(); |
| |
| if (limited_max_freq == MSM_CPUFREQ_NO_LIMIT) |
| return; |
| |
| for_each_possible_cpu(cpu) { |
| update_cpu_max_freq(cpu, MSM_CPUFREQ_NO_LIMIT); |
| } |
| } |
| |
| static int set_enabled(const char *val, const struct kernel_param *kp) |
| { |
| int ret = 0; |
| |
| ret = param_set_bool(val, kp); |
| if (!enabled) |
| disable_msm_thermal(); |
| else |
| pr_info("msm_thermal: no action for enabled = %d\n", enabled); |
| |
| pr_info("msm_thermal: enabled = %d\n", enabled); |
| |
| return ret; |
| } |
| |
| static struct kernel_param_ops module_ops = { |
| .set = set_enabled, |
| .get = param_get_bool, |
| }; |
| |
| module_param_cb(enabled, &module_ops, &enabled, 0644); |
| MODULE_PARM_DESC(enabled, "enforce thermal limit on cpu"); |
| |
| int __devinit msm_thermal_init(struct msm_thermal_data *pdata) |
| { |
| int ret = 0; |
| |
| BUG_ON(!pdata); |
| BUG_ON(pdata->sensor_id >= TSENS_MAX_SENSORS); |
| memcpy(&msm_thermal_info, pdata, sizeof(struct msm_thermal_data)); |
| |
| enabled = 1; |
| INIT_DELAYED_WORK(&check_temp_work, check_temp); |
| schedule_delayed_work(&check_temp_work, 0); |
| |
| return ret; |
| } |
| |
| static int __devinit msm_thermal_dev_probe(struct platform_device *pdev) |
| { |
| int ret = 0; |
| char *key = NULL; |
| struct device_node *node = pdev->dev.of_node; |
| struct msm_thermal_data data; |
| |
| memset(&data, 0, sizeof(struct msm_thermal_data)); |
| key = "qcom,sensor-id"; |
| ret = of_property_read_u32(node, key, &data.sensor_id); |
| if (ret) |
| goto fail; |
| WARN_ON(data.sensor_id >= TSENS_MAX_SENSORS); |
| |
| key = "qcom,poll-ms"; |
| ret = of_property_read_u32(node, key, &data.poll_ms); |
| if (ret) |
| goto fail; |
| |
| key = "qcom,limit-temp"; |
| ret = of_property_read_u32(node, key, &data.limit_temp_degC); |
| if (ret) |
| goto fail; |
| |
| key = "qcom,temp-hysteresis"; |
| ret = of_property_read_u32(node, key, &data.temp_hysteresis_degC); |
| if (ret) |
| goto fail; |
| |
| key = "qcom,freq-step"; |
| ret = of_property_read_u32(node, key, &data.freq_step); |
| |
| fail: |
| if (ret) |
| pr_err("%s: Failed reading node=%s, key=%s\n", |
| __func__, node->full_name, key); |
| else |
| ret = msm_thermal_init(&data); |
| |
| return ret; |
| } |
| |
| static struct of_device_id msm_thermal_match_table[] = { |
| {.compatible = "qcom,msm-thermal"}, |
| {}, |
| }; |
| |
| static struct platform_driver msm_thermal_device_driver = { |
| .probe = msm_thermal_dev_probe, |
| .driver = { |
| .name = "msm-thermal", |
| .owner = THIS_MODULE, |
| .of_match_table = msm_thermal_match_table, |
| }, |
| }; |
| |
| int __init msm_thermal_device_init(void) |
| { |
| return platform_driver_register(&msm_thermal_device_driver); |
| } |