ACPI: battery: add power_{now,avg} properties to power_class

ACPI has smart batteries, which work in units of energy and measure
rate of (dis)charge as power, thus it is not appropriate to export it
as a current_now. Current_now will still be exported to allow
for userland applications to match.

Signed-off-by: Alexey Starikovskiy <astarikovskiy@suse.de>
Signed-off-by: Len Brown <len.brown@intel.com>
diff --git a/include/linux/power_supply.h b/include/linux/power_supply.h
index 8ff25e0..594c494 100644
--- a/include/linux/power_supply.h
+++ b/include/linux/power_supply.h
@@ -73,6 +73,8 @@
 	POWER_SUPPLY_PROP_VOLTAGE_AVG,
 	POWER_SUPPLY_PROP_CURRENT_NOW,
 	POWER_SUPPLY_PROP_CURRENT_AVG,
+	POWER_SUPPLY_PROP_POWER_NOW,
+	POWER_SUPPLY_PROP_POWER_AVG,
 	POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
 	POWER_SUPPLY_PROP_CHARGE_EMPTY_DESIGN,
 	POWER_SUPPLY_PROP_CHARGE_FULL,