IB/mthca: fix QP size limits for mem-free HCAs
Unlike tavor, the max work queue size is an exact power of 2 for arbel
mode, despite what the documentation (of the QUERY_DEV_LIM firmware
command) says. Without this patch, on Arbel, we can start with a QP
of a valid size and get above the reported limit after rounding to the
next power of two.
Signed-off-by: Jack Morgenstein <jackm@mellanox.co.il>
Signed-off-by: Michael S. Tsirkin <mst@mellanox.co.il>
Signed-off-by: Roland Dreier <rolandd@cisco.com>