ASoC: wcd9xxx: Wait enough time during mbhc calibration

If mbhc micbias has a capacitor which is large enough to delay micbias
voltage ramp up/down, initial calibration also needs to delay enough time
after changing mux to be able to calibrate ground and micbias voltage
accurately.  Increase delay to 50ms during calibration and improve
calibration accuracy.

Change-Id: Ibdc124495a4455464d5874f33ed1547aec664242
Signed-off-by: Joonwoo Park <joonwoop@codeaurora.org>
1 file changed