msm: camera: Fix color corruption for 8960V2.

New PCA rolloff for 8960V2 was causing color corruption. Fixed it by
writing rolloff tables to the DMI with correct offset. Also DMI HI and LO
words were swaped to get the correct MSB/LSB order.

Change-Id: I21f1811cdf48a744e7cc424a81874c5103f1365b
Signed-off-by: Ujwal Patel <ujwalp@codeaurora.org>
1 file changed