r8169: reset IntrStatus after chip reset

Original comment (Karsten):
On a MSI MS-6702E mainboard, when in rtl8169_init_one() for the first time
after BIOS has run, IntrStatus reads 5 after chip has been reset.
IntrStatus should equal 0 there, so patch changes IntrStatus reset to happen
after chip reset instead of before.

Remark (Francois):
Assuming that the loglevel of the driver is increased above NETIF_MSG_INTR,
the bug reveals itself with a typical "interrupt 0025 in poll" message
at startup. In retrospect, the message should had been read as an hint of
an unexpected hardware state several months ago :o(

Fixes (at least part of) https://bugzilla.redhat.com/show_bug.cgi?id=460747

Signed-off-by: Karsten Wiese <fzu@wemgehoertderstaat.de>
Signed-off-by: Francois Romieu <romieu@fr.zoreil.com>
Tested-by: Josep <josep.puigdemont@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
1 file changed