ASoC: wcd9xxx: Distortion in HPH LO combo device

Follow Class H sequence for headset, lineout and ear concurrency as per
the class H HW design sequence to avoid signal clipping.

CRs-Fixed: 602408,618992
Change-Id: I517a5df98708f7292111e5cf71ffcf6ef8c4b870
Signed-off-by: Sudheer Papothi <spapothi@codeaurora.org>