blob: e472df8423236d8a095d3763a95464ce13a0d334 [file] [log] [blame]
Tilman Schmidt27d1ac22006-04-10 22:55:15 -07001GigaSet 307x Device Driver
2==========================
3
41. Requirements
5 ------------
61.1. Hardware
7 --------
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +00008 This driver supports the connection of the Gigaset 307x/417x family of
Tilman Schmidt27d1ac22006-04-10 22:55:15 -07009 ISDN DECT bases via Gigaset M101 Data, Gigaset M105 Data or direct USB
10 connection. The following devices are reported to be compatible:
Tilman Schmidt2869b232007-02-12 00:52:34 -080011
12 Bases:
13 Siemens Gigaset 3070/3075 isdn
14 Siemens Gigaset 4170/4175 isdn
15 Siemens Gigaset SX205/255
16 Siemens Gigaset SX353
17 T-Com Sinus 45 [AB] isdn
18 T-Com Sinus 721X[A] [SE]
Tilman Schmidt27d1ac22006-04-10 22:55:15 -070019 Vox Chicago 390 ISDN (KPN Telecom)
Tilman Schmidt2869b232007-02-12 00:52:34 -080020
21 RS232 data boxes:
22 Siemens Gigaset M101 Data
23 T-Com Sinus 45 Data 1
24
25 USB data boxes:
26 Siemens Gigaset M105 Data
27 Siemens Gigaset USB Adapter DECT
28 T-Com Sinus 45 Data 2
29 T-Com Sinus 721 data
Tilman Schmidt27d1ac22006-04-10 22:55:15 -070030 Chicago 390 USB (KPN)
Tilman Schmidt2869b232007-02-12 00:52:34 -080031
Tilman Schmidt27d1ac22006-04-10 22:55:15 -070032 See also http://www.erbze.info/sinus_gigaset.htm and
33 http://gigaset307x.sourceforge.net/
34
35 We had also reports from users of Gigaset M105 who could use the drivers
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +000036 with SX 100 and CX 100 ISDN bases (only in unimodem mode, see section 2.5.)
Tilman Schmidt27d1ac22006-04-10 22:55:15 -070037 If you have another device that works with our driver, please let us know.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -070038
39 Chances of getting an USB device to work are good if the output of
40 lsusb
41 at the command line contains one of the following:
42 ID 0681:0001
43 ID 0681:0002
44 ID 0681:0009
45 ID 0681:0021
46 ID 0681:0022
47
481.2. Software
49 --------
50 The driver works with ISDN4linux and so can be used with any software
51 which is able to use ISDN4linux for ISDN connections (voice or data).
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +000052 Experimental Kernel CAPI support is available as a compilation option.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -070053
54 There are some user space tools available at
55 http://sourceforge.net/projects/gigaset307x/
56 which provide access to additional device specific functions like SMS,
57 phonebook or call journal.
58
59
602. How to use the driver
61 ---------------------
622.1. Modules
63 -------
Tilman Schmidtc69c6d12009-04-05 06:39:33 +000064 For the devices to work, the proper kernel modules have to be loaded.
65 This normally happens automatically when the system detects the USB
66 device (base, M105) or when the line discipline is attached (M101). It
67 can also be triggered manually using the modprobe(8) command, for example
68 for troubleshooting or to pass module parameters.
Tilman Schmidt2869b232007-02-12 00:52:34 -080069
70 The module ser_gigaset provides a serial line discipline N_GIGASET_M101
Tilman Schmidt64f16602009-12-05 08:54:20 +000071 which uses the regular serial port driver to access the device, and must
72 therefore be attached to the serial device to which the M101 is connected.
73 The ldattach(8) command (included in util-linux-ng release 2.14 or later)
74 can be used for that purpose, for example:
75 ldattach GIGASET_M101 /dev/ttyS1
Tilman Schmidtc69c6d12009-04-05 06:39:33 +000076 This will open the device file, attach the line discipline to it, and
77 then sleep in the background, keeping the device open so that the line
78 discipline remains active. To deactivate it, kill the daemon, for example
79 with
Tilman Schmidt64f16602009-12-05 08:54:20 +000080 killall ldattach
Tilman Schmidtc69c6d12009-04-05 06:39:33 +000081 before disconnecting the device. To have this happen automatically at
82 system startup/shutdown on an LSB compatible system, create and activate
83 an appropriate LSB startup script /etc/init.d/gigaset. (The init name
84 'gigaset' is officially assigned to this project by LANANA.)
85 Alternatively, just add the 'ldattach' command line to /etc/rc.local.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -070086
Tilman Schmidt64f16602009-12-05 08:54:20 +000087 The modules accept the following parameters:
88
89 Module Parameter Meaning
90
91 gigaset debug debug level (see section 3.2.)
92
93 startmode initial operation mode (see section 2.5.):
94 bas_gigaset ) 1=ISDN4linux/CAPI (default), 0=Unimodem
95 ser_gigaset )
96 usb_gigaset ) cidmode initial Call-ID mode setting (see section
97 2.5.): 1=on (default), 0=off
98
99 Depending on your distribution you may want to create a separate module
100 configuration file /etc/modprobe.d/gigaset for these, or add them to a
101 custom file like /etc/modprobe.conf.local.
102
Tilman Schmidt27d1ac22006-04-10 22:55:15 -07001032.2. Device nodes for user space programs
104 ------------------------------------
105 The device can be accessed from user space (eg. by the user space tools
106 mentioned in 1.2.) through the device nodes:
107
Tilman Schmidt2869b232007-02-12 00:52:34 -0800108 - /dev/ttyGS0 for M101 (RS232 data boxes)
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700109 - /dev/ttyGU0 for M105 (USB data boxes)
110 - /dev/ttyGB0 for the base driver (direct USB connection)
111
Tilman Schmidt64f16602009-12-05 08:54:20 +0000112 If you connect more than one device of a type, they will get consecutive
113 device nodes, eg. /dev/ttyGU1 for a second M105.
114
115 You can also set a "default device" for the user space tools to use when
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700116 no device node is given as parameter, by creating a symlink /dev/ttyG to
117 one of them, eg.:
118
Tilman Schmidt64f16602009-12-05 08:54:20 +0000119 ln -s /dev/ttyGB0 /dev/ttyG
120
121 The devices accept the following device specific ioctl calls
122 (defined in gigaset_dev.h):
123
124 ioctl(int fd, GIGASET_REDIR, int *cmd);
125 If cmd==1, the device is set to be controlled exclusively through the
126 character device node; access from the ISDN subsystem is blocked.
127 If cmd==0, the device is set to be used from the ISDN subsystem and does
128 not communicate through the character device node.
129
130 ioctl(int fd, GIGASET_CONFIG, int *cmd);
131 (ser_gigaset and usb_gigaset only)
132 If cmd==1, the device is set to adapter configuration mode where commands
133 are interpreted by the M10x DECT adapter itself instead of being
134 forwarded to the base station. In this mode, the device accepts the
135 commands described in Siemens document "AT-Kommando Alignment M10x Data"
136 for setting the operation mode, associating with a base station and
137 querying parameters like field strengh and signal quality.
138 Note that there is no ioctl command for leaving adapter configuration
139 mode and returning to regular operation. In order to leave adapter
140 configuration mode, write the command ATO to the device.
141
142 ioctl(int fd, GIGASET_BRKCHARS, unsigned char brkchars[6]);
143 (usb_gigaset only)
144 Set the break characters on an M105's internal serial adapter to the six
145 bytes stored in brkchars[]. Unused bytes should be set to zero.
146
147 ioctl(int fd, GIGASET_VERSION, unsigned version[4]);
148 Retrieve version information from the driver. version[0] must be set to
149 one of:
150 - GIGVER_DRIVER: retrieve driver version
151 - GIGVER_COMPAT: retrieve interface compatibility version
152 - GIGVER_FWBASE: retrieve the firmware version of the base
153 Upon return, version[] is filled with the requested version information.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700154
1552.3. ISDN4linux
156 ----------
157 This is the "normal" mode of operation. After loading the module you can
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +0000158 set up the ISDN system just as you'd do with any ISDN card supported by
159 the ISDN4Linux subsystem. Most distributions provide some configuration
160 utility. If not, you can use some HOWTOs like
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700161 http://www.linuxhaven.de/dlhp/HOWTO/DE-ISDN-HOWTO-5.html
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +0000162 If this doesn't work, because you have some device like SX100 where
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700163 debug output (see section 3.2.) shows something like this when dialing
164 CMD Received: ERROR
165 Available Params: 0
166 Connection State: 0, Response: -1
167 gigaset_process_response: resp_code -1 in ConState 0 !
168 Timeout occurred
Tilman Schmidt64f16602009-12-05 08:54:20 +0000169 you probably need to use unimodem mode. (see section 2.5.)
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700170
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +00001712.4. CAPI
172 ----
173 If the driver is compiled with CAPI support (kernel configuration option
174 GIGASET_CAPI, experimental) it can also be used with CAPI 2.0 kernel and
Tilman Schmidt64f16602009-12-05 08:54:20 +0000175 user space applications. For user space access, the module capi.ko must
176 be loaded. The capiinit command (included in the capi4k-utils package)
177 does this for you.
178
179 The CAPI variant of the driver supports legacy ISDN4Linux applications
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +0000180 via the capidrv compatibility driver. The kernel module capidrv.ko must
Tilman Schmidt64f16602009-12-05 08:54:20 +0000181 be loaded explicitly with the command
182 modprobe capidrv
183 if needed, and cannot be unloaded again without unloading the driver
184 first. (These are limitations of capidrv.)
185
186 The note about unimodem mode in the preceding section applies here, too.
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +0000187
1882.5. Unimodem mode
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700189 -------------
190 This is needed for some devices [e.g. SX100] as they have problems with
191 the "normal" commands.
192
193 If you have installed the command line tool gigacontr, you can enter
194 unimodem mode using
195 gigacontr --mode unimodem
196 You can switch back using
197 gigacontr --mode isdn
198
Tilman Schmidt64f16602009-12-05 08:54:20 +0000199 You can also put the driver directly into Unimodem mode when it's loaded,
200 by passing the module parameter startmode=0 to the hardware specific
201 module, e.g.
202 modprobe usb_gigaset startmode=0
203 or by adding a line like
204 options usb_gigaset startmode=0
205 to an appropriate module configuration file, like /etc/modprobe.d/gigaset
206 or /etc/modprobe.conf.local.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700207
208 In this mode the device works like a modem connected to a serial port
209 (the /dev/ttyGU0, ... mentioned above) which understands the commands
210 ATZ init, reset
211 => OK or ERROR
212 ATD
213 ATDT dial
214 => OK, CONNECT,
215 BUSY,
216 NO DIAL TONE,
217 NO CARRIER,
218 NO ANSWER
219 <pause>+++<pause> change to command mode when connected
220 ATH hangup
221
222 You can use some configuration tool of your distribution to configure this
223 "modem" or configure pppd/wvdial manually. There are some example ppp
Hansjoerg Lipp3dda4e32006-04-22 18:43:00 +0200224 configuration files and chat scripts in the gigaset-VERSION/ppp directory
225 in the driver packages from http://sourceforge.net/projects/gigaset307x/.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700226 Please note that the USB drivers are not able to change the state of the
Tilman Schmidtb88bd952009-05-13 12:44:18 +0000227 control lines. This means you must use "Stupid Mode" if you are using
228 wvdial or you should use the nocrtscts option of pppd.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700229 You must also assure that the ppp_async module is loaded with the parameter
230 flag_time=0. You can do this e.g. by adding a line like
231
232 options ppp_async flag_time=0
233
Tilman Schmidt64f16602009-12-05 08:54:20 +0000234 to an appropriate module configuration file, like /etc/modprobe.d/gigaset
235 or /etc/modprobe.conf.local.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700236
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +00002372.6. Call-ID (CID) mode
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700238 ------------------
239 Call-IDs are numbers used to tag commands to, and responses from, the
240 Gigaset base in order to support the simultaneous handling of multiple
241 ISDN calls. Their use can be enabled ("CID mode") or disabled ("Unimodem
242 mode"). Without Call-IDs (in Unimodem mode), only a very limited set of
243 functions is available. It allows outgoing data connections only, but
244 does not signal incoming calls or other base events.
245
246 DECT cordless data devices (M10x) permanently occupy the cordless
247 connection to the base while Call-IDs are activated. As the Gigaset
248 bases only support one DECT data connection at a time, this prevents
249 other DECT cordless data devices from accessing the base.
250
251 During active operation, the driver switches to the necessary mode
252 automatically. However, for the reasons above, the mode chosen when
253 the device is not in use (idle) can be selected by the user.
254 - If you want to receive incoming calls, you can use the default
255 settings (CID mode).
256 - If you have several DECT data devices (M10x) which you want to use
257 in turn, select Unimodem mode by passing the parameter "cidmode=0" to
Tilman Schmidt64f16602009-12-05 08:54:20 +0000258 the appropriate driver module (ser_gigaset or usb_gigaset).
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700259
260 If you want both of these at once, you are out of luck.
261
Tilman Schmidt64f16602009-12-05 08:54:20 +0000262 You can also use the tty class parameter "cidmode" of the device to
263 change its CID mode while the driver is loaded, eg.
264 echo 0 > /sys/class/tty/ttyGU0/cidmode
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700265
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +00002662.7. Unregistered Wireless Devices (M101/M105)
Tilman Schmidtb3fcb132009-05-13 12:44:17 +0000267 -----------------------------------------
268 The main purpose of the ser_gigaset and usb_gigaset drivers is to allow
269 the M101 and M105 wireless devices to be used as ISDN devices for ISDN
270 connections through a Gigaset base. Therefore they assume that the device
271 is registered to a DECT base.
272
273 If the M101/M105 device is not registered to a base, initialization of
274 the device fails, and a corresponding error message is logged by the
275 driver. In that situation, a restricted set of functions is available
276 which includes, in particular, those necessary for registering the device
277 to a base or for switching it between Fixed Part and Portable Part
Tilman Schmidt64f16602009-12-05 08:54:20 +0000278 modes. See the gigacontr(8) manpage for details.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700279
2803. Troubleshooting
281 ---------------
2823.1. Solutions to frequently reported problems
283 -----------------------------------------
284 Problem:
285 You have a slow provider and isdn4linux gives up dialing too early.
286 Solution:
287 Load the isdn module using the dialtimeout option. You can do this e.g.
288 by adding a line like
289
290 options isdn dialtimeout=15
291
Tilman Schmidt64f16602009-12-05 08:54:20 +0000292 to /etc/modprobe.d/gigaset, /etc/modprobe.conf.local or a similar file.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700293
294 Problem:
Tilman Schmidt2ac2ed52010-02-22 13:08:51 +0000295 The isdnlog program emits error messages or just doesn't work.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700296 Solution:
Tilman Schmidt2ac2ed52010-02-22 13:08:51 +0000297 Isdnlog supports only the HiSax driver. Do not attempt to use it with
298 other drivers such as Gigaset.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700299
300 Problem:
301 You have two or more DECT data adapters (M101/M105) and only the
302 first one you turn on works.
303 Solution:
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +0000304 Select Unimodem mode for all DECT data adapters. (see section 2.5.)
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700305
Tilman Schmidtc69c6d12009-04-05 06:39:33 +0000306 Problem:
Tilman Schmidtb3fcb132009-05-13 12:44:17 +0000307 Messages like this:
308 usb_gigaset 3-2:1.0: Could not initialize the device.
309 appear in your syslog.
310 Solution:
311 Check whether your M10x wireless device is correctly registered to the
Tilman Schmidt7bb5fdc2009-10-06 12:19:17 +0000312 Gigaset base. (see section 2.7.)
Tilman Schmidtb3fcb132009-05-13 12:44:17 +0000313
Tilman Schmidt27d1ac22006-04-10 22:55:15 -07003143.2. Telling the driver to provide more information
315 ----------------------------------------------
316 Building the driver with the "Gigaset debugging" kernel configuration
317 option (CONFIG_GIGASET_DEBUG) gives it the ability to produce additional
318 information useful for debugging.
319
320 You can control the amount of debugging information the driver produces by
321 writing an appropriate value to /sys/module/gigaset/parameters/debug, e.g.
322 echo 0 > /sys/module/gigaset/parameters/debug
323 switches off debugging output completely,
Tilman Schmidt2ac2ed52010-02-22 13:08:51 +0000324 echo 0x302020 > /sys/module/gigaset/parameters/debug
325 enables a reasonable set of debugging output messages. These values are
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700326 bit patterns where every bit controls a certain type of debugging output.
327 See the constants DEBUG_* in the source file gigaset.h for details.
328
329 The initial value can be set using the debug parameter when loading the
330 module "gigaset", e.g. by adding a line
331 options gigaset debug=0
Tilman Schmidt64f16602009-12-05 08:54:20 +0000332 to your module configuration file, eg. /etc/modprobe.d/gigaset or
333 /etc/modprobe.conf.local.
Tilman Schmidt27d1ac22006-04-10 22:55:15 -0700334
335 Generated debugging information can be found
336 - as output of the command
337 dmesg
338 - in system log files written by your syslog daemon, usually
339 in /var/log/, e.g. /var/log/messages.
340
3413.3. Reporting problems and bugs
342 ---------------------------
343 If you can't solve problems with the driver on your own, feel free to
344 use one of the forums, bug trackers, or mailing lists on
345 http://sourceforge.net/projects/gigaset307x
346 or write an electronic mail to the maintainers.
347
348 Try to provide as much information as possible, such as
349 - distribution
350 - kernel version (uname -r)
351 - gcc version (gcc --version)
352 - hardware architecture (uname -m, ...)
353 - type and firmware version of your device (base and wireless module,
354 if any)
355 - output of "lsusb -v" (if using an USB device)
356 - error messages
357 - relevant system log messages (it would help if you activate debug
358 output as described in 3.2.)
359
360 For help with general configuration problems not specific to our driver,
361 such as isdn4linux and network configuration issues, please refer to the
362 appropriate forums and newsgroups.
363
3643.4. Reporting problem solutions
365 ---------------------------
366 If you solved a problem with our drivers, wrote startup scripts for your
367 distribution, ... feel free to contact us (using one of the places
368 mentioned in 3.3.). We'd like to add scripts, hints, documentation
369 to the driver and/or the project web page.
370
371
3724. Links, other software
373 ---------------------
374 - Sourceforge project developing this driver and associated tools
375 http://sourceforge.net/projects/gigaset307x
376 - Yahoo! Group on the Siemens Gigaset family of devices
377 http://de.groups.yahoo.com/group/Siemens-Gigaset
378 - Siemens Gigaset/T-Sinus compatibility table
379 http://www.erbze.info/sinus_gigaset.htm
380
381
3825. Credits
383 -------
384 Thanks to
385
386 Karsten Keil
387 for his help with isdn4linux
388 Deti Fliegl
389 for his base driver code
390 Dennis Dietrich
391 for his kernel 2.6 patches
392 Andreas Rummel
393 for his work and logs to get unimodem mode working
394 Andreas Degert
395 for his logs and patches to get cx 100 working
396 Dietrich Feist
397 for his generous donation of one M105 and two M101 cordless adapters
398 Christoph Schweers
399 for his generous donation of a M34 device
400
401 and all the other people who sent logs and other information.