Linus Torvalds | 1da177e | 2005-04-16 15:20:36 -0700 | [diff] [blame] | 1 | /* |
| 2 | * Comtrol SV11 card driver |
| 3 | * |
| 4 | * This is a slightly odd Z85230 synchronous driver. All you need to |
| 5 | * know basically is |
| 6 | * |
| 7 | * Its a genuine Z85230 |
| 8 | * |
| 9 | * It supports DMA using two DMA channels in SYNC mode. The driver doesn't |
| 10 | * use these facilities |
| 11 | * |
| 12 | * The control port is at io+1, the data at io+3 and turning off the DMA |
| 13 | * is done by writing 0 to io+4 |
| 14 | * |
| 15 | * The hardware does the bus handling to avoid the need for delays between |
| 16 | * touching control registers. |
| 17 | * |
| 18 | * Port B isnt wired (why - beats me) |
| 19 | */ |
| 20 | |
| 21 | #include <linux/module.h> |
| 22 | #include <linux/kernel.h> |
| 23 | #include <linux/mm.h> |
| 24 | #include <linux/net.h> |
| 25 | #include <linux/skbuff.h> |
| 26 | #include <linux/netdevice.h> |
| 27 | #include <linux/if_arp.h> |
| 28 | #include <linux/delay.h> |
| 29 | #include <linux/ioport.h> |
| 30 | #include <net/arp.h> |
| 31 | |
Al Viro | 8272997 | 2005-12-06 05:53:04 -0500 | [diff] [blame] | 32 | #include <asm/irq.h> |
Linus Torvalds | 1da177e | 2005-04-16 15:20:36 -0700 | [diff] [blame] | 33 | #include <asm/io.h> |
| 34 | #include <asm/dma.h> |
| 35 | #include <asm/byteorder.h> |
| 36 | #include <net/syncppp.h> |
| 37 | #include "z85230.h" |
| 38 | |
| 39 | static int dma; |
| 40 | |
| 41 | struct sv11_device |
| 42 | { |
| 43 | void *if_ptr; /* General purpose pointer (used by SPPP) */ |
| 44 | struct z8530_dev sync; |
| 45 | struct ppp_device netdev; |
| 46 | }; |
| 47 | |
| 48 | /* |
| 49 | * Network driver support routines |
| 50 | */ |
| 51 | |
| 52 | /* |
| 53 | * Frame receive. Simple for our card as we do sync ppp and there |
| 54 | * is no funny garbage involved |
| 55 | */ |
| 56 | |
| 57 | static void hostess_input(struct z8530_channel *c, struct sk_buff *skb) |
| 58 | { |
| 59 | /* Drop the CRC - it's not a good idea to try and negotiate it ;) */ |
| 60 | skb_trim(skb, skb->len-2); |
| 61 | skb->protocol=__constant_htons(ETH_P_WAN_PPP); |
Arnaldo Carvalho de Melo | 98e399f | 2007-03-19 15:33:04 -0700 | [diff] [blame] | 62 | skb_reset_mac_header(skb); |
Linus Torvalds | 1da177e | 2005-04-16 15:20:36 -0700 | [diff] [blame] | 63 | skb->dev=c->netdevice; |
| 64 | /* |
| 65 | * Send it to the PPP layer. We don't have time to process |
| 66 | * it right now. |
| 67 | */ |
| 68 | netif_rx(skb); |
| 69 | c->netdevice->last_rx = jiffies; |
| 70 | } |
| 71 | |
| 72 | /* |
| 73 | * We've been placed in the UP state |
| 74 | */ |
| 75 | |
| 76 | static int hostess_open(struct net_device *d) |
| 77 | { |
| 78 | struct sv11_device *sv11=d->priv; |
| 79 | int err = -1; |
| 80 | |
| 81 | /* |
| 82 | * Link layer up |
| 83 | */ |
| 84 | switch(dma) |
| 85 | { |
| 86 | case 0: |
| 87 | err=z8530_sync_open(d, &sv11->sync.chanA); |
| 88 | break; |
| 89 | case 1: |
| 90 | err=z8530_sync_dma_open(d, &sv11->sync.chanA); |
| 91 | break; |
| 92 | case 2: |
| 93 | err=z8530_sync_txdma_open(d, &sv11->sync.chanA); |
| 94 | break; |
| 95 | } |
| 96 | |
| 97 | if(err) |
| 98 | return err; |
| 99 | /* |
| 100 | * Begin PPP |
| 101 | */ |
| 102 | err=sppp_open(d); |
| 103 | if(err) |
| 104 | { |
| 105 | switch(dma) |
| 106 | { |
| 107 | case 0: |
| 108 | z8530_sync_close(d, &sv11->sync.chanA); |
| 109 | break; |
| 110 | case 1: |
| 111 | z8530_sync_dma_close(d, &sv11->sync.chanA); |
| 112 | break; |
| 113 | case 2: |
| 114 | z8530_sync_txdma_close(d, &sv11->sync.chanA); |
| 115 | break; |
| 116 | } |
| 117 | return err; |
| 118 | } |
| 119 | sv11->sync.chanA.rx_function=hostess_input; |
| 120 | |
| 121 | /* |
| 122 | * Go go go |
| 123 | */ |
| 124 | |
| 125 | netif_start_queue(d); |
| 126 | return 0; |
| 127 | } |
| 128 | |
| 129 | static int hostess_close(struct net_device *d) |
| 130 | { |
| 131 | struct sv11_device *sv11=d->priv; |
| 132 | /* |
| 133 | * Discard new frames |
| 134 | */ |
| 135 | sv11->sync.chanA.rx_function=z8530_null_rx; |
| 136 | /* |
| 137 | * PPP off |
| 138 | */ |
| 139 | sppp_close(d); |
| 140 | /* |
| 141 | * Link layer down |
| 142 | */ |
| 143 | netif_stop_queue(d); |
| 144 | |
| 145 | switch(dma) |
| 146 | { |
| 147 | case 0: |
| 148 | z8530_sync_close(d, &sv11->sync.chanA); |
| 149 | break; |
| 150 | case 1: |
| 151 | z8530_sync_dma_close(d, &sv11->sync.chanA); |
| 152 | break; |
| 153 | case 2: |
| 154 | z8530_sync_txdma_close(d, &sv11->sync.chanA); |
| 155 | break; |
| 156 | } |
| 157 | return 0; |
| 158 | } |
| 159 | |
| 160 | static int hostess_ioctl(struct net_device *d, struct ifreq *ifr, int cmd) |
| 161 | { |
| 162 | /* struct sv11_device *sv11=d->priv; |
| 163 | z8530_ioctl(d,&sv11->sync.chanA,ifr,cmd) */ |
| 164 | return sppp_do_ioctl(d, ifr,cmd); |
| 165 | } |
| 166 | |
| 167 | static struct net_device_stats *hostess_get_stats(struct net_device *d) |
| 168 | { |
| 169 | struct sv11_device *sv11=d->priv; |
| 170 | if(sv11) |
| 171 | return z8530_get_stats(&sv11->sync.chanA); |
| 172 | else |
| 173 | return NULL; |
| 174 | } |
| 175 | |
| 176 | /* |
| 177 | * Passed PPP frames, fire them downwind. |
| 178 | */ |
| 179 | |
| 180 | static int hostess_queue_xmit(struct sk_buff *skb, struct net_device *d) |
| 181 | { |
| 182 | struct sv11_device *sv11=d->priv; |
| 183 | return z8530_queue_xmit(&sv11->sync.chanA, skb); |
| 184 | } |
| 185 | |
| 186 | static int hostess_neigh_setup(struct neighbour *n) |
| 187 | { |
| 188 | if (n->nud_state == NUD_NONE) { |
| 189 | n->ops = &arp_broken_ops; |
| 190 | n->output = n->ops->output; |
| 191 | } |
| 192 | return 0; |
| 193 | } |
| 194 | |
| 195 | static int hostess_neigh_setup_dev(struct net_device *dev, struct neigh_parms *p) |
| 196 | { |
| 197 | if (p->tbl->family == AF_INET) { |
| 198 | p->neigh_setup = hostess_neigh_setup; |
| 199 | p->ucast_probes = 0; |
| 200 | p->mcast_probes = 0; |
| 201 | } |
| 202 | return 0; |
| 203 | } |
| 204 | |
| 205 | static void sv11_setup(struct net_device *dev) |
| 206 | { |
| 207 | dev->open = hostess_open; |
| 208 | dev->stop = hostess_close; |
| 209 | dev->hard_start_xmit = hostess_queue_xmit; |
| 210 | dev->get_stats = hostess_get_stats; |
| 211 | dev->do_ioctl = hostess_ioctl; |
| 212 | dev->neigh_setup = hostess_neigh_setup_dev; |
| 213 | } |
| 214 | |
| 215 | /* |
| 216 | * Description block for a Comtrol Hostess SV11 card |
| 217 | */ |
| 218 | |
| 219 | static struct sv11_device *sv11_init(int iobase, int irq) |
| 220 | { |
| 221 | struct z8530_dev *dev; |
| 222 | struct sv11_device *sv; |
| 223 | |
| 224 | /* |
| 225 | * Get the needed I/O space |
| 226 | */ |
| 227 | |
| 228 | if(!request_region(iobase, 8, "Comtrol SV11")) |
| 229 | { |
| 230 | printk(KERN_WARNING "hostess: I/O 0x%X already in use.\n", iobase); |
| 231 | return NULL; |
| 232 | } |
| 233 | |
Robert P. J. Day | 5cbded5 | 2006-12-13 00:35:56 -0800 | [diff] [blame] | 234 | sv = kmalloc(sizeof(struct sv11_device), GFP_KERNEL); |
Linus Torvalds | 1da177e | 2005-04-16 15:20:36 -0700 | [diff] [blame] | 235 | if(!sv) |
| 236 | goto fail3; |
| 237 | |
| 238 | memset(sv, 0, sizeof(*sv)); |
| 239 | sv->if_ptr=&sv->netdev; |
| 240 | |
| 241 | sv->netdev.dev = alloc_netdev(0, "hdlc%d", sv11_setup); |
| 242 | if(!sv->netdev.dev) |
| 243 | goto fail2; |
| 244 | |
| 245 | SET_MODULE_OWNER(sv->netdev.dev); |
| 246 | |
| 247 | dev=&sv->sync; |
| 248 | |
| 249 | /* |
| 250 | * Stuff in the I/O addressing |
| 251 | */ |
| 252 | |
| 253 | dev->active = 0; |
| 254 | |
| 255 | dev->chanA.ctrlio=iobase+1; |
| 256 | dev->chanA.dataio=iobase+3; |
| 257 | dev->chanB.ctrlio=-1; |
| 258 | dev->chanB.dataio=-1; |
| 259 | dev->chanA.irqs=&z8530_nop; |
| 260 | dev->chanB.irqs=&z8530_nop; |
| 261 | |
| 262 | outb(0, iobase+4); /* DMA off */ |
| 263 | |
| 264 | /* We want a fast IRQ for this device. Actually we'd like an even faster |
| 265 | IRQ ;) - This is one driver RtLinux is made for */ |
| 266 | |
Thomas Gleixner | 1fb9df5 | 2006-07-01 19:29:39 -0700 | [diff] [blame] | 267 | if(request_irq(irq, &z8530_interrupt, IRQF_DISABLED, "Hostess SV11", dev)<0) |
Linus Torvalds | 1da177e | 2005-04-16 15:20:36 -0700 | [diff] [blame] | 268 | { |
| 269 | printk(KERN_WARNING "hostess: IRQ %d already in use.\n", irq); |
| 270 | goto fail1; |
| 271 | } |
| 272 | |
| 273 | dev->irq=irq; |
| 274 | dev->chanA.private=sv; |
| 275 | dev->chanA.netdevice=sv->netdev.dev; |
| 276 | dev->chanA.dev=dev; |
| 277 | dev->chanB.dev=dev; |
| 278 | |
| 279 | if(dma) |
| 280 | { |
| 281 | /* |
| 282 | * You can have DMA off or 1 and 3 thats the lot |
| 283 | * on the Comtrol. |
| 284 | */ |
| 285 | dev->chanA.txdma=3; |
| 286 | dev->chanA.rxdma=1; |
| 287 | outb(0x03|0x08, iobase+4); /* DMA on */ |
| 288 | if(request_dma(dev->chanA.txdma, "Hostess SV/11 (TX)")!=0) |
| 289 | goto fail; |
| 290 | |
| 291 | if(dma==1) |
| 292 | { |
| 293 | if(request_dma(dev->chanA.rxdma, "Hostess SV/11 (RX)")!=0) |
| 294 | goto dmafail; |
| 295 | } |
| 296 | } |
| 297 | |
| 298 | /* Kill our private IRQ line the hostess can end up chattering |
| 299 | until the configuration is set */ |
| 300 | disable_irq(irq); |
| 301 | |
| 302 | /* |
| 303 | * Begin normal initialise |
| 304 | */ |
| 305 | |
| 306 | if(z8530_init(dev)!=0) |
| 307 | { |
| 308 | printk(KERN_ERR "Z8530 series device not found.\n"); |
| 309 | enable_irq(irq); |
| 310 | goto dmafail2; |
| 311 | } |
| 312 | z8530_channel_load(&dev->chanB, z8530_dead_port); |
| 313 | if(dev->type==Z85C30) |
| 314 | z8530_channel_load(&dev->chanA, z8530_hdlc_kilostream); |
| 315 | else |
| 316 | z8530_channel_load(&dev->chanA, z8530_hdlc_kilostream_85230); |
| 317 | |
| 318 | enable_irq(irq); |
| 319 | |
| 320 | |
| 321 | /* |
| 322 | * Now we can take the IRQ |
| 323 | */ |
| 324 | if(dev_alloc_name(dev->chanA.netdevice,"hdlc%d")>=0) |
| 325 | { |
| 326 | struct net_device *d=dev->chanA.netdevice; |
| 327 | |
| 328 | /* |
| 329 | * Initialise the PPP components |
| 330 | */ |
| 331 | sppp_attach(&sv->netdev); |
| 332 | |
| 333 | /* |
| 334 | * Local fields |
| 335 | */ |
| 336 | |
| 337 | d->base_addr = iobase; |
| 338 | d->irq = irq; |
| 339 | d->priv = sv; |
| 340 | |
| 341 | if(register_netdev(d)) |
| 342 | { |
| 343 | printk(KERN_ERR "%s: unable to register device.\n", |
| 344 | d->name); |
| 345 | sppp_detach(d); |
| 346 | goto dmafail2; |
| 347 | } |
| 348 | |
| 349 | z8530_describe(dev, "I/O", iobase); |
| 350 | dev->active=1; |
| 351 | return sv; |
| 352 | } |
| 353 | dmafail2: |
| 354 | if(dma==1) |
| 355 | free_dma(dev->chanA.rxdma); |
| 356 | dmafail: |
| 357 | if(dma) |
| 358 | free_dma(dev->chanA.txdma); |
| 359 | fail: |
| 360 | free_irq(irq, dev); |
| 361 | fail1: |
| 362 | free_netdev(sv->netdev.dev); |
| 363 | fail2: |
| 364 | kfree(sv); |
| 365 | fail3: |
| 366 | release_region(iobase,8); |
| 367 | return NULL; |
| 368 | } |
| 369 | |
| 370 | static void sv11_shutdown(struct sv11_device *dev) |
| 371 | { |
| 372 | sppp_detach(dev->netdev.dev); |
| 373 | unregister_netdev(dev->netdev.dev); |
| 374 | z8530_shutdown(&dev->sync); |
| 375 | free_irq(dev->sync.irq, dev); |
| 376 | if(dma) |
| 377 | { |
| 378 | if(dma==1) |
| 379 | free_dma(dev->sync.chanA.rxdma); |
| 380 | free_dma(dev->sync.chanA.txdma); |
| 381 | } |
| 382 | release_region(dev->sync.chanA.ctrlio-1, 8); |
| 383 | free_netdev(dev->netdev.dev); |
| 384 | kfree(dev); |
| 385 | } |
| 386 | |
| 387 | #ifdef MODULE |
| 388 | |
| 389 | static int io=0x200; |
| 390 | static int irq=9; |
| 391 | |
| 392 | module_param(io, int, 0); |
| 393 | MODULE_PARM_DESC(io, "The I/O base of the Comtrol Hostess SV11 card"); |
| 394 | module_param(dma, int, 0); |
| 395 | MODULE_PARM_DESC(dma, "Set this to 1 to use DMA1/DMA3 for TX/RX"); |
| 396 | module_param(irq, int, 0); |
| 397 | MODULE_PARM_DESC(irq, "The interrupt line setting for the Comtrol Hostess SV11 card"); |
| 398 | |
| 399 | MODULE_AUTHOR("Alan Cox"); |
| 400 | MODULE_LICENSE("GPL"); |
| 401 | MODULE_DESCRIPTION("Modular driver for the Comtrol Hostess SV11"); |
| 402 | |
| 403 | static struct sv11_device *sv11_unit; |
| 404 | |
| 405 | int init_module(void) |
| 406 | { |
| 407 | printk(KERN_INFO "SV-11 Z85230 Synchronous Driver v 0.03.\n"); |
| 408 | printk(KERN_INFO "(c) Copyright 2001, Red Hat Inc.\n"); |
| 409 | if((sv11_unit=sv11_init(io,irq))==NULL) |
| 410 | return -ENODEV; |
| 411 | return 0; |
| 412 | } |
| 413 | |
| 414 | void cleanup_module(void) |
| 415 | { |
| 416 | if(sv11_unit) |
| 417 | sv11_shutdown(sv11_unit); |
| 418 | } |
| 419 | |
| 420 | #endif |
| 421 | |