commit | 4f81ed8e1a9398b032ae7a8c979b9ebb76406a2a | [log] [tgz] |
---|---|---|
author | Yann Gautier <yann.gautier@st.com> | Fri Nov 06 15:32:25 2020 +0100 |
committer | Yann Gautier <yann.gautier@foss.st.com> | Mon Mar 08 18:15:26 2021 +0100 |
tree | be463e9767e1b197d269a579b47a77be676c395d | |
parent | 2c62b00e8c4b327165a4bfd874714aa460f3e176 [diff] |
tzc400: correct FAIL_CONTROL Privileged bit When bit 20 of TZC400 Fail control register [1] is set to 1, it means Privileged access, the macros FAIL_CONTROL_PRIV_PRIV and FAIL_CONTROL_PRIV_UNPRIV are then updated to reflect this. [1] https://developer.arm.com/documentation/ddi0504/c/programmers-model/register-descriptions/fail-control-register?lang=en Change-Id: I01e522fded5cf66c9827293ddcf543c79f9e509e Signed-off-by: Yann Gautier <yann.gautier@st.com>